background image

14

Two quarter-turn brackets are supplied with the device if it is to be 
flown above the ground. Remove the floor stand/base and rig the P-5 
to a support truss or structure using the supplied brackets and suitable 
clamps.

Fasten a safety cable (not shown) between the 
support structure and the attachment point on 
the device. The safety cable must be able to 
bear at least 10 times the weight of the device.

The device can be tilted from 0° - 180°. To adjust the tilt angle, loosen the two tilt screws, 
one of each side of the device, tilt the device to the angle required and 
re-tighten the screws.

CAUTION:

 

If the device has been operating, always allow it to cool for 15 minutes 

before handling.

WARNING! 

Always secure an elevated P-5 with a safety cable as backup.

Manual_P-5_170x113,3.book  Page 14  Monday, January 12, 2015  9:24 AM

Содержание P-5 TW POI

Страница 1: ...P 5 WASH LIGHT P 5 WHITE P 5 TUNABLE WHITE Manual_P 5_170x113 3 book Page 1 Monday January 12 2015 9 24 AM...

Страница 2: ...2 P 5 series dimensions Measurements in millimetres and inches in brackets Drawing not to scale Manual_P 5_170x113 3 book Page 2 Monday January 12 2015 9 24 AM...

Страница 3: ...tion contained in this manual The SGM logo the SGM name and all other trademarks in this document pertaining to services or products by SGM or its affiliates and subsidiaries are trademarks owned or l...

Страница 4: ...uring the device 16 Configuring the device using an Android telephone via RFID 16 Master Slave configuration 17 Setting a static color manually 18 Using stand alone operation 19 Connecting to a DMX co...

Страница 5: ...ce personality settings 26 Setting the dimming curve 26 Flipping the OLED display 26 Setting the OLED display saver 26 Setting the fan mode 27 Service 28 Changing lens module 28 Upgrading the firmware...

Страница 6: ...6 Devices and accessories 55 Included items 55 Ordering information 55 User s notes 57 Manual_P 5_170x113 3 book Page 6 Monday January 12 2015 9 24 AM...

Страница 7: ...struction and operation of the device and the hazards involved Preventing electric shock Always power off unplug the device before removing any covers Ensure that the power is turned off when connecti...

Страница 8: ...ilding codes Ensure a minimum clearance of 0 1 m 4 in around the cooling fans Do not paint cover or modify the device Keep all flammable materials away from the device Allow the device to cool for 15...

Страница 9: ...ring surface with suitable corrosion resistant hardware For temporary installation with clamps ensure that the quarter turn fasteners are turned fully and secured with a suitable safety cable The cabl...

Страница 10: ...ty to adjust white color temperature to 2200 3000 4000 or 5300K The P 5 s all provide built in wireless DMX support stand alone programs dimming and a lamp life expectancy of 50 000 hours The P 5 s al...

Страница 11: ...44 x 10 W LEDs B Base C Safety wire eyelet D Cooling fans E Tilt lock F DMX in and out G Wireless antenna socket H OLED display I Control panel J Power connections K Tilt lock Manual_P 5_170x113 3 bo...

Страница 12: ...locations This means that it is protected from Dust to the degree that dust cannot enter the device in sufficient quantities as to interfere with its operation Lower pressure jets of water from any d...

Страница 13: ...l you may wish to fab ricate a rain shield above the device or modify the position and orientation of the device to minimize pooling For permanent installation on the ground remove the rubber feet fro...

Страница 14: ...on the device The safety cable must be able to bear at least 10 times the weight of the device The device can be tilted from 0 180 To adjust the tilt angle loosen the two tilt screws one of each side...

Страница 15: ...wer supply must incorporate a fuse or circuit breaker for fault protection After connecting the P 5 to power run the on board test using the Test Automated test menu to ensure that the device and each...

Страница 16: ...p of the device Navigate the menus and options using the arrow buttons and select items using the Enter button The options available are listed in Control menu on page 45 After powering the P 5 on the...

Страница 17: ...n becomes a slave device or an entire group of P 5 devices which then becomes slave devices The assigned slave device s will mimic the settings of the master device Use the Manual Master Slave menu to...

Страница 18: ...rol menu on page 31 Note that whenever the Manual Quick color settings are changed the device will be set by default to automatically start in quick color mode whenever it is powered on This can be re...

Страница 19: ...fade in time for the transition from one color or white to the next and a wait static time each of up to 999 minutes and 59 seconds in duration To define a stand alone program use the Manual Editor me...

Страница 20: ...r outdoor installations use only IP rated XLR connectors suitable for outdoor use Enabling the wireless cone antenna receiver Before you enable the wireless cone antenna ensure that there is no DMX ca...

Страница 21: ...the device Attach the wireless DMX an tenna to the connector on the back of the device Use the Settings Wireless DMX Enable menu to activate wireless DMX and the Settings Wireless DMX Wireless LED Sta...

Страница 22: ...ddress of 13 If two or more DMX devices of the same type have the same DMX address then they will mimic each other s behavior Incorrect settings will result in un predictable responses to the lighting...

Страница 23: ...color channels for red green blue White is automatically mixed in 4 Individual control of color channels for red green blue and white RGBW 6 RGBW dimmer shutter strobe pulse open shutter effects 8 RGB...

Страница 24: ...mperature control 2200K 3000K 4000K and 5300K shutter strobe pulse and open shutter effects 8 Fine and coarse control of white temperatures 2200K 3000K 4000K and 5300K P 5 W DMX modes Function 1 Dimme...

Страница 25: ...g when you mix 2 or 3 colors to ensure uniform color between products Adjusting 1 color does not activate full color calibration If you want to be able to mix raw RGB colors without full color calibra...

Страница 26: ...vice is installed hanging upside down it might be useful to flip the display so that it is easier to read To flip the display use the Settings Flip display menu or press the up and down buttons on the...

Страница 27: ...where low noise is a requirement or where the device will be operating in high temperatures it is possible to adjust the default fan speed to low or high using the Settings Fan mode menu Manual_P 5_17...

Страница 28: ...is likely to damage the ingress protection Consult your SGM dealer if the device operates abnormally is defective or otherwise in need of service or repair Changing lens module To replace the lens mod...

Страница 29: ...highlighted front plugs with an Unbrako 6 HOP6 Allen key 3 Take out the lens module 4 Place the new lens on the PCB print spacers and carefully press the lens module in place Manual_P 5_170x113 3 boo...

Страница 30: ...h an Unbrako 6 HOP6 Allen key Nm 1 0 and place three Silica Gel bags not included in lens kit as shown 6 Place the sealing frame facing upwards see below on top of the lens module Manual_P 5_170x113 3...

Страница 31: ...your SGM distributor Cleaning To maintain optimal performance regular cleaning is essential Cleaning schedules will vary depending on the operating environment and the installation should therefore b...

Страница 32: ...tomatic White Channel Name DMX value DMX percentage Description Info Default DMX value Fader type 1 RED 0 255 0 0 100 0 No RED Maximum RED 0 0 Fade 2 GREEN 0 255 0 0 100 0 No GREEN Maximum GREEN 0 0 F...

Страница 33: ...ue Fader type 1 RED 0 255 0 0 100 0 No RED Maximum RED 0 0 Fade 2 GREEN 0 255 0 0 100 0 No GREEN Maximum GREEN 0 0 Fade 3 BLUE 0 255 0 0 100 0 No BLUE Maximum BLUE 0 0 Fade 4 WHITE 0 255 0 0 100 0 No...

Страница 34: ...Fast Slow 0 0 152 175 59 6 68 6 Pulse Open Slow Fast 0 0 176 199 69 0 78 0 Pulse Close Slow Fast 0 0 200 244 78 4 95 7 Strobe Random Slow Fast 0 0 245 255 96 1 100 0 Open 0 0 2 Intensity 0 255 0 0 100...

Страница 35: ...LUE Maximum BLUE 0 0 Fade 6 WHITE 0 255 0 0 100 0 No WHITE Maximum WHITE 0 0 Fade Channel Name DMX value DMX percentage Description Info Default DMX value Fader type Manual_P 5_170x113 3 book Page 35...

Страница 36: ...der type 1 2 RED 0 65535 0 0 100 0 No RED Maximum RED 0 0 Fade 3 4 GREEN 0 65535 0 0 100 0 No GREEN Maximum GREEN 0 0 Fade 5 6 BLUE 0 65535 0 0 100 0 No BLUE Maximum BLUE 0 0 Fade 7 8 WHITE 0 65535 0...

Страница 37: ...5 0 0 100 0 No light Maximum light 0 0 Fade 2 3 RED 0 65535 0 0 100 0 No RED Maximum RED 0 0 Fade 4 5 GREEN 0 65535 0 0 100 0 No GREEN Maximum GREEN 0 0 Fade 6 7 BLUE 0 65535 0 0 100 0 No BLUE Maximum...

Страница 38: ...535 0 0 100 0 No light Maximum light 0 0 Fade 3 4 RED 0 65535 0 0 100 0 No RED Maximum RED 0 0 Fade 5 6 GREEN 0 65535 0 0 100 0 No GREEN Maximum GREEN 0 0 Fade 7 8 BLUE 0 65535 0 0 100 0 No BLUE Maxim...

Страница 39: ...nnel Mode Intensity Channel Name DMX value DMX percentage Description Info Default DMX value Fader type 1 Intensity 0 255 0 0 100 0 No light Maximum light 0 0 Fade Manual_P 5_170x113 3 book Page 39 Mo...

Страница 40: ...9 Snap 8 15 3 1 5 9 Open 0 0 16 151 6 3 59 2 Strobe Fast Slow 0 0 152 175 59 6 68 6 Pulse Open Slow Fast 0 0 176 199 69 0 78 0 Pulse Close Slow Fast 0 0 200 244 78 4 95 7 Strobe Random Slow Fast 0 0...

Страница 41: ...Intensity Channel Name DMX value DMX percentage Description Info Default DMX value Fader type 1 2 Intensity 0 65535 0 0 100 0 No light Maximum light 0 0 Fade Manual_P 5_170x113 3 book Page 41 Monday...

Страница 42: ...255 0 0 100 0 No light Maximum light 0 0 Fade 2 CTC 0 255 0 0 100 0 2200K 5300K 0 0 Fade Channel Name DMX value DMX percentage Description Info Default DMX value Fader type 1 WHITE 0 255 0 0 100 0 22...

Страница 43: ...0 0 16 151 6 3 59 2 Strobe Fast Slow 0 0 152 175 59 6 68 6 Pulse Open Slow Fast 0 0 176 199 69 0 78 0 Pulse Close Slow Fast 0 0 200 244 78 4 95 7 Strobe Random Slow Fast 0 0 245 255 96 1 100 0 Open 0...

Страница 44: ...Description Info Default DMX value Fader type 1 2 WHITE 0 65535 0 0 100 0 2200K 0 0 Fade 3 4 WHITE 0 65535 0 0 100 0 3000K 0 0 Fade 5 6 WHITE 0 65535 0 0 100 0 4000K 0 0 Fade 7 8 WHITE 0 65535 0 0 100...

Страница 45: ...product type Firmware Version Displays installed software version Serial Number Displays serial number RDM ID Displays RDM ID for use with the SGM Tool App DMX View Displays received DMX levels Temper...

Страница 46: ...use only Settings Wireless DMX Log Off Sends log off command to W DMX system Wireless LED Flashing not connected to data Solid connected to data Enable Enables wireless DMX operation Disable Disables...

Страница 47: ...nd alone program 1 2 or 3 Only used if the startup mode is set to stand alone 1 is default Dimming Curve Linear Provides equal resolution dimming from 0 100 Gamma Corrected Provides high resolution di...

Страница 48: ...l is not in use Fan Mode Standard Adjust fan speed relative to internal device temperature Silent Low fan speed for quiet operation Max Power High fan speed for maximum cooling effect Always Full Powe...

Страница 49: ...values continued Min White P 5 Min Line 1 P 5 W Min Line 2 P 5 W Min Line 3 P 5 W Min Line 4 P 5 W Min 3000 P 5 TW Min 2200 P 5 TW Level 1 Level 2 Level 3 Function Manual_P 5_170x113 3 book Page 49 M...

Страница 50: ...to factory default settings Service Pin Service Menu Manual Quick Color Red P 5 Static quick color red mix 0 255 Sets device to quick color startup mode Green P 5 Static quick color green mix 0 255 Se...

Страница 51: ...device to quick color startup mode 3000K P 5 TW Static quick color white temperature 3000K mix 0 255 Sets device to quick color startup mode 4000K P 5 TW Static quick color white temperature 4000K mi...

Страница 52: ...ted scene 0 255 Blue P 5 Blue value in currently selected scene 0 255 White P 5 P 5 W White value in currently selected scene 0 255 2200K P 5 TW 2200K white temperature value in currently selected sce...

Страница 53: ...Variable Strobe 16 151 Pulse Open 152 175 Pulse Close 176 199 Variable Random Strobe 200 244 Shutter Open 245 255 Fade Time Min Fade in transition time to current scene in min 0 999 Fade Time Sec Fad...

Страница 54: ...rrent scene in sec 0 59 Test Off Stops test sequence execution Automated Test Initiates a self test sequence Burn in Test 30 min Service use only Display Test Service use only Level 1 Level 2 Level 3...

Страница 55: ...t 21 Order no 83061103 P 5 Lens Kit 15 Order no 83061102 BBC 2 Dual Bracket Order no 83060603 BBC 4 Quad Bracket Order no 83060604 Floor Stand for P Q and X series with 1 4 turn fasteners Order no 830...

Страница 56: ...o 166 Conforms to UL Std 1573 Conforms to 2006 95 EC Low Voltage Directive Conforms to 2011 65 EU RoHS2 Directive RoHS 4008543 The information in this document is subject to change without notice Manu...