background image

page 

4

2 - Fixture Maintenance

2.1 Access to internal components

Giotto fixtures have a simple mechanism for
opening the moving head. To open fixture,
just turn the two locking screws shown in
the design through 180°, then lift the cover.
Before opening the fixture after it has been
used, wait for at least 30 minutes to allow
all the parts to cool down and avoid burns
All work must ALWAYS be carried out by qualified technical personnel.
When the work is finished, close the fixture again, making certain that the mechanical parts fit
perfectly together.

2.2 Lamp fitting, adjustment and replacement

To ensure the ideal lamp/optics combina-
tion, every time a new lamp is fitted, a lit-
tle adjustment may be required to optimi-
ze light output. 
On the rear of Giotto’s moving head, the-
re’s a flange with two large screws, which
enable the removal of the flange, on the
rear of which the lampholder is fitted.

ATTENTION: making certain that the fix-
ture is switched off and the parts are not
sufficiently hot to cause burns (wait for at least 30 minutes after switching the unit off).

Once the lamp has been fitted in the lampholder, make certain that it has been fitted perfectly and
then lock the flange back in place on the rear of the fixture.
There are three hexagonal screws on the centre of the flange for centring the lamp, which must
be done with the fixture on, without dimming the light and (of course), with the shutter open and
the strobe off.
This procedure requires precision and care and DEFINITELY MUST only be carried out by quali-
fied experienced technical personnel.

MSR 1200

To prevent burning, wait for at least 30 minuts after

turning the switch off before opening the projector

Attendere almeno 30 minuti dallo spegnimento

prima di aprire il proiettore

• Switch off the appliance before opening •

• Non aprire prima di avere tolto la tensione •

• Vor dem öffnen, den strom Ausschalten •

• Antes de abrir la tapa, desconectar la maquina •

• Avant d'ouvrir, s'assurer que l'appareil il n'est pas sous tension •

Axial lamp regulation

(relamp only by

qualified person)

Regolazione

assiale lampada

(sostituzione riservata

al personale
qualificato)

Do not obstruct airflow to vents

Non ostruire le griglie di protezione delle ventole

Содержание Giotto WASH 1200

Страница 1: ...rel 1 00 Giotto professional moving head wash luminaire WASH WASH 1200 user manual...

Страница 2: ...e following conditions In places subject to excessive humidity In places subject to vibrations or bumps In places with a temperature of more than 45 C or less than 2 C Protect the fixture from excessi...

Страница 3: ...8 Chapter 3 8 Lamp ignition meter 8 Chapter 3 9 Fixture elapsed time meter 9 Chapter 3 10 Input signal 9 Chapter 3 11 Pan Tilt resolution 9 Chapter 3 12 Remote lamp control 9 Chapter 3 13 Remote fixt...

Страница 4: ...ility up to SGM s usual standards The smart lines and optimisation of the outer structure to ensure user friendliness enable the fix ture to be installed in absolutely any position and any maintenance...

Страница 5: ...se burns wait for at least 30 minutes after switching the unit off Once the lamp has been fitted in the lampholder make certain that it has been fitted perfectly and then lock the flange back in place...

Страница 6: ...lified personnel with the fixture switched off and after waiting at least 30 minutes for the internal parts of the moving head to cool down 2 5 Periodic cleaning and checks The fixture should be clean...

Страница 7: ...nly the controls sent to that specific unit To address the fixture press ENTER will appear on the display with the word Addr flashing The Up Down keys now allow the value required to be entered Press...

Страница 8: ...enu with Up Down or will appear To change the direction of rotation press ENTER and then change from Norm to Rev or vice versa with the Up Down keys then press ENTER to confirm the new choice 3 5 Limi...

Страница 9: ...r or UP to restore the value Undo function 3 8 Lamp ignition meter Giotto s microcomputer stores various data in its memory including those relative to the number of times the lamp has been switched o...

Страница 10: ...the controller or desk to be used 3 12 Remote lamp switching Operators can decide if the lamp has to be switched on from the controller or automatically To access to this function scroll with Up Down...

Страница 11: ...Down then press ENTER again 3 15 Display reading angle When the fixture is hung head downwards from a structure the display messages can be rota ted through 180 thus facilitating access to the program...

Страница 12: ...be used over the colours created by the CMY system 4 4 Ch 6 CMY system Cyan Wheel This channel is part of the CMY colour mixing group which creates colours using an additive method i e superimposing...

Страница 13: ...00 4 8 Ch 10 Shutter and Strobe This channel controls the opening and closing of the shutter and the Giotto s strobe effect The strobe is enabled according to the values shown on the table alongside 4...

Страница 14: ...n alongside When the value set is between 251 and 255 the time depends on the cross fade time set on the controller 4 11 Ch 13 Remote lamp switching and reset When the operator enables the remote lamp...

Страница 15: ...cod M001190 Via Pio La Torre 1 61010 TAVULLIA PS ITALY Tel 39 0721476477 Fax 39 0721476170 www sgm it info sgm it...

Отзывы: