10
Installation / Rigging
WARNING! Always secure elevated devices with a safety cable.
The G-Spot may be installed in any orientation.
Always use two Omega brackets to rig the device. Lock each brack-
et with both 1/4-turn fasteners. The fasteners are locked only when
turned fully clockwise.
Always fasten safety cables between the load-bearing support
structure and the attachment points on the device. The safety
cables must be able to bear at least 10 times the weight of the
device.
CAUTION
:
• Always use two safety wires.
• Min. safety wire gauge = 5 mm.
• Max. safety wire length (free fall) = 30 cm (11 in.)
• Make sure the slack of the safety wire is at a minimum.
• Never use the carrying handles for secondary attachment.
Manual_G_Spot_EN_170x113,3.book Page 10 Thursday, October 30, 2014 1:04 PM