7.2.1 SET DISTANCE 4mA
Press ENTER to display the distance value associated with 4mA output.
Use SCROLL and UP ARROW to modify that value; in the example the 4mA
distance is 3500mm.
Press ENTER to con
fi
rm.
DISTANCE 4mA
DISTANCE 20mA
MEDIUM
FILTER COEFFICENT
BLIND DISTANCE
DISPLAY
Ź
3500 mm
SET DISTANCE 4mA
7.2.2 SET DISTANCE 20mA
Press ENTER to display the distance value associated with 20mA output.
Use SCROLL and UP ARROW to modify that value; in the example the 20mA
distance is 500mm.
Press ENTER to con
fi
rm..
DISTANCE 4mA
DISTANCE 20mA
MEDIUM
FILTER COEFFICENT
BLIND DISTANCE
DISPLAY
Ź
0500 mm
SET DISTANCE 20mA
100%
0%
Distance 20mA
Distance 4mA
Le
vel me
asur
ament
Referent point
PTU50-51-56