background image

 

 

7. SGK AL-12 PRE USE INSPECTION PROCEDURES  

  

  

Warning 

 

Never assume that the SGK AL-12 AirLight Lifter is ready to use straight 
out of the box, the tool should be carefully inspected prior to operating to 
ensure that the tool and the operating parts as depicted in the illustration 
on page 5 are in a serviceable condition. 

 

It is the responsibility of the SGK AL-12 AirLight Lifter operator to inspect 
and check the tool prior to use. If the tool is found to be defective in any 
way remove the tool from service and contact SGK Lifters Pty Ltd.

 

8. SGK AL-12 ELECTRICAL WARNING

 

 

 Danger Warning 

 

 

Risk of electric shock.  

 

Failure to observe the following warnings may result in 
personal injury, death or equipment damage. 

 

It should be noted that the SGK AL-12 AirLight Lifter is not an electrically 
insulated device and should be treated with caution when operating. 

 

Before  attempting  to  service  the  luminaire  fixture  the  circuit  must  be 
isolated and locked out.  

 

The constant current regulator must also be electrically isolated so that 
the circuit cannot be energised by remote means. 

 

The  circuit  must  have  no  power  and  be  proved  de-energised  prior  to 
commencement of work. 

 

Allow sufficient time for the luminaire fixture to cool as the high interior 
temperatures may cause severe burns. 

 

SGK AL-12 AirLight Lifter R-01                                                                                                 Page 6

 

Содержание AL-12

Страница 1: ......

Страница 2: ...RES 6 8 SGK AL 12 ELECTRICAL WARNINGS 6 9 SGK AL 12 OPERATING PERSONNEL QUALIFICATIONS 7 10 SGK AL 12 PERSONAL PROTECTIVE EQUIPMENT 7 11 SGK AL 12 PINCH POINT WARNING 8 12 SGK AL 12 NONCOMPLIANCE CLAU...

Страница 3: ...ifters Pty Ltd has placed the safety of the operator as the number one priority With this in mind prior to operating the SGK AL 12 AirLight Lifter it is very important that the information documented...

Страница 4: ...n personal injury death or equipment damage CAUTION SIGN Failure to observe a caution may result in equipment damage INSTRUCTION MANUAL FAMILIARISATION SIGN Before using the tool the operating instruc...

Страница 5: ...ning The warnings and safety instructions as documented in the SGK AL 12 AirLight Lifter manual are not meant to cover all of the possible operating conditions and situations that may occur The operat...

Страница 6: ...utside of the design limitations or the manufacturer s specified use may result in the degradation of performance damage or failure of the SGK AL 12 AirLight Lifter SGK Lifters Pty Ltd considers any a...

Страница 7: ...ER PARTS IDENTIFICATION 1 Non Slip Guards 6 Reflective Tape 2 Soft Grip Handle 7 Leverage Point 3 Magnet 8 Fixed Extraction Bar 4 Pivot 9 Pivoted Extraction Bar 5 Lever 10 Extraction Pins SGK AL 12 Ai...

Страница 8: ...CTRICAL WARNING Danger Warning Risk of electric shock Failure to observe the following warnings may result in personal injury death or equipment damage It should be noted that the SGK AL 12 AirLight L...

Страница 9: ...tool Airfield lighting maintenance personnel should be physically capable of performing the required task 10 SGK AL 12 PERSONAL PROTECTIVE EQUIPMENT Warning PPE Compliance Failure to observe the follo...

Страница 10: ...ted within the user manual may result in an injury or may cause damage to the SGK AL 12 AirLight Lifter SGK Lifters Pty Ltd accepts no responsibility for the improper use of the SGK AL 12 AirLight Lif...

Страница 11: ...n One General Use Section One Step 1 USING THE APPROPRIATE TOOL CAREFULLY REMOVE THE LUMINAIRE FIXTURE RETAINING FASTNERS Section One Step 2 USING THE MAGNET CAREFULLY REMOVE WASHERS Note Some washers...

Страница 12: ...D DOWNWARD PRESSURE ON LEVER TO RELEASE ONE SIDE OF THE LUMINAIRE FIXTURE Section One Step 4 A FIT LEVER INTO THE OPPOSITE HOLE PROVIDED IN THE LUMINAIRE FIXTURE B WITH THE LEVER ANGLED DOWNWARDS APPL...

Страница 13: ...IFTING HOLE PROVIDED ON THE INSET LUMINAIRE FIXTURE Note Always use pivot extraction bar to engage first Section One Step 6 ENGAGE FIXED EXTRACTION BAR IN THE SECOND LIFTING HOLE PROVIDED IN THE LUMIN...

Страница 14: ...THODS LIFT THE LUMINAIRE FIXTURE FROM THE CANISTER SHOULD YOU ENCOUNTER ANY LIFTING RESISTANCE FOLLOW STEPS IN SECTION TWO FOR REMOVING TOOL FROM LUMINAIRE FIXTURE AND THEN RETURN TO THE PROCEDURE OUT...

Страница 15: ...fixture Section Two Step 1 A PULL BACK SLIGHTLY ON PIVOT B LIFT REAR OF TOOL JUST ENOUGH TO RELEASE FIXED EXTRACTION BAR Section Two Step 2 A PUSH PIVOT FORWARD WHIST KEEPING TOOL AS LEVEL AS POSSIBLE...

Страница 16: ...12 HANDLING AND STORAGE The SGK AL 12 AirLight Lifter should be handled carefully at all times When not in use the tool should be stored in an appropriate manner in the box provided for this purpose A...

Страница 17: ...n environmentally compatible recycling facility 17 LIABILITY STATEMENT SGK AL 12 AirLight Lifter R 01 Page 15 Warning Unauthorised operation and use of the SGK AL 12 AirLight Lifter may result in pers...

Страница 18: ...Ltd s judgment or opinion as to affect the product b Any SGK AirLight Lifter which has in SGK Lifters Pty Ltd s judgment or opinion been subject to negligence accident or improper storage c Any SGK Li...

Страница 19: ...The warranty period for the products is 12 months from the date of sale Warranty is void if the product has been tampered with modified or altered by the user PLEASE NOTE CLAIMS FOR WARRANTY Before r...

Страница 20: ...TRALIA Telephone 61 405 302 994 info airlightlifter com au sales airlightlifter com au www airlightlifter com au DESIGNED ENGINEERED AND QUALITY ASSURED IN AUSTRALIA MADE IN VIETNAM PATENT PENDING COP...

Отзывы: