1. Introduction

This is a digital device, able to measure all the variables associated with an electrical line, as is
shown in the following table. It accepts the three current and three voltages signals in a 4 wire
configuration. It is also possible to use it in 3 wire configuration, using two or three current
transformers.

2. Features and Technical Parameters

2.1 Features

The operating hours& the consuming power are shown in a alternate display but have

synchronous display—to be displayed at the same time on the same screen.

The meter has the function to memorize all the data when the power off .When the machine is

switched on again after the power off ,the measurement data should continue running on and
show the summing up amount in numbers. ( Note:the meter can not show the data when power
off )

The meter has the displaying of the voltage, current, power, MD.

The meter has reset function. People can reset the data through Modbus RTU communication

2.2 Technical Parameters

Voltage:

3*220/380V

Current:

3*3(6)A

Accuracy:

1.0

Frequency:

50-60Hz

Auxiliary supply:

60-400V

Impulse Constant:

1000imp/kWh, 1000imp/kvarh

Display Mode:

128*64 LCD dot matrix display

Power Consumption:

1W,<8VA

Starting current:

0.4%Ib

Working temperature:

-20 70

Average humidity value of year:

75%

Содержание sge-353

Страница 1: ......

Страница 2: ...meter has the function to memorize all the data when the power off When the machine is switched on again after the power off the measurement data should continue running on and show the summing up amo...

Страница 3: ...set the energy you must select the current reset page to operate Key2 Key4 Enter into set interface Key3 Key4 Starting up to check the meter password Material Case Grey flame resistant ABS Panel Grey...

Страница 4: ...1 14 Voltage Ua Ub Uc 2 14 Current Ia Ib Ic 3 14 Power Pa Pb Pc 4 14 React Power Qa Qb Qc 5 14 Act Power Sa Sb Sc 6 14 Voltage Uab Ubc Uca 7 14 P F PFa PFb Pc 8 14 THD current THD Ia THD Ib THD Ic 9 1...

Страница 5: ...t primary 0 99999A Secondary 5A Page 3 ID Meter communication address broadcast address 0 1 255 Page4 Baud Baud rate 1200 to 9600 Page5 MD period Select time 1 30min Page6 Password Change password XXX...

Страница 6: ...the panel meter to relative position see Fig 3 Fig 3 Then install these two black clips back to the panel meter two sides should be strictly installed see Fig 4 Making the connection according to the...

Страница 7: ...ve the instruction can result in death serious injury or considerable material damage Safe carrying capacity of rubber or plastic insulated wire 1 specification mm nominal cross section mm2 Safe carry...

Страница 8: ...t to technical modifications without notice General Warning After removing the packaging make sure the integrity of the unit If in doubt don t use the equipment and contact technical staff Mounting of...

Отзывы: