56
Englis
h
7.3 Overload indicator.
In normal use the output indicator (green) is ON.
If the power outputs reach the rated power (about 3000W) the overload
indicator light flash showing we are near to limit of power.
If the power outputs reach and keep the max power for some seconds, power
output will be OFF to avoid damage in generator.
To reset output power follows the next steps:
1 First unplug all devices connect in generator.
2 Stop generators, after some seconds restart again.
3 Wait 2 minutes and then connect again the device in generator.
If the overload protector trips again after connecting the devices, do not plug the
device. The plugged device may have a problem or exceeds the generator's
power.
NOTE: Once you verify that the generator cannot support or accept the
load, please do not insist.
Regular overloads may affect the group despite
all of its advanced protections.
Remember that many types of equipment need extra consumption for startup.
Equipment’s that use motors such as compressors, water pumps, circular saws,
grinders or others similar consume up to 3 times more power for startup. For
example, a 500W water pump will need 1500W to start up; therefore we would
need a generator no less than 1500W.
(RED) OVERLOAD
INDICATOR LIGHT
Содержание 3200W E.START
Страница 2: ......
Страница 38: ......
Страница 74: ...English...
Страница 110: ......
Страница 111: ......
Страница 112: ...AVENIDA DEL EBRO 12 CALAHORRA LA RIOJA...