All calculations therefore have to be checked and approved by the responsible planner ahead of execution. 

The user is responsible to assure compliance with all applicable laws and regulations.

SFS intec AG

Division Construction

Rosenbergsaustrasse 20

CH-9435 Heerbrugg

[email protected]

www.sfs.biz

3.1

Panel must lie on  

a hard surface

 

3.2

Keep a right angle 

during the setting 

process

Push the GESIPA

® 

PowerBird

®

 Pro 

slightly towards  

the panel

  

2.2

There is a gap 

between the 

TU-fastener head and 

the bracket

2.3

Giving heavy force  

to the TU-fastener 

while not removeing 

the mandrel can 

cause damage to  

the panel

thickness

6

  0

-0,1

ø

Bracket

+0,5  0

Drill depth

L

6,5

ø

-7,0

12

2.2

3.1

 

          

2.3

3.2

 

         

2. Position the bracket

3. Remove mandrel

Position the pre-drilled bracket over the hole in the panel and push through the TU-fastener

Remove the mandrel using the GESIPA

®

 PowerBird

®

 Pro riveting tool combined with nose piece 17/36 or 17/40 

Dimension must be kept