4.7 R
Reading oof tthe cconfiguration
Reading of the input parameters
Reading of the measure display parameters
Reading of the analog output parameters
(option analog output)
Reading of the communication parameters
(option digital output)
Reading of the LOGIC input parameters
(option TOR)
Reading of the alarm parameters
(option 2 or 4 relays)
Reading of the safety parameters in case of
self-diagnosis error
Reading of the display programming para-
meters (leds, bargraph leds..)
Reading of the instrument own parameters
In each reading submenu, press
and
to move, and
to visualise parameters.
If no key is pressed during 20s, the instrument will automatically
revert to measure display.
OFF
LO
HI
·
On the relays :
No influence of a self-diagnosis error on the relay
Relay de-activated (coil not supplied) in case of self-diagnosis
error
Relay active (coil supplied) in case of self-diagnosis error
Note : The led is either still or lit according to its programming in the
menu
rELAY.
·
On the analog output
If a return value has been entered
Value included between :
0 and 22 mA (current output)
or
0 and 11 V (voltage output)
br.diG
1 1 1 1
4444
diSP.1
diSP.2
diSP.3
Cut.I
Cut.U
FiLt.
4.6.5 Display features :
Choice of the parameter dedicated to the display n°1
Choice of the parameter dedicated to the display n°2
Choice of the parameter dedicated to the display n°3
Cut-off on the current programmable from 1.0% to 15.0% in
manual caliber, from 0.2% to 15.0% of caliber 5A in auto caliber
Cut-off on the voltage programmable from 1.0% to 20.0% in
manual caliber, from 0.3% to 20.0% of caliber 500V in auto caliber
Choice of the digital filtering : OFF , 1 , 2 ; increase the value
in case of unsteady measures.
••
Response time
:
Typical response time : 110ms.
Note : For the analog output response time, add 40 ms to the above value.
For the relays : add the time delay programmed on the alarms.
••
Setting of the digits brightness
Lowest brightness
Strongest brightness
nuLL
nuLL
YES
=
nuLL
no
YES
=
=
nuLL
••
Deleting of unsignificant zeros
Suppresses the unsignificant zeros on the left hand
side.
Eg.
: Display value 0015
Display 0015
Display 15
Eg.
: Display value 00.15
Display 00.15
Display 0.15
no
YES
=
=
1 1 1 1
4444
br.bAr
L.dIG
••
Setting of the brightness of the bargraph and leds
Lowest brightness
Strongest brightness
The brightness level is visualised directly on leds 5 to 8 and on the
bargraph.
Caution
: during the setting, the 4 leds and the bargraph no longer repre-
sent the measure, including in mode reading.
••
Inhibition of the last digit
(low weight)
In the programming mode, the menu L.dIG allows deleting the display of
the last digit, enforcing it to 0 if OFF is validated.
••
Bargraph display factor
(option bargraph only)
Value of the display parameter X corresponding to 0% of the
bargraph
Value of the display parameter X corresponding to 100% of the
bargraph
In case of overstepping, the bargraph starts to blink.
d.bArX
F.bArX
rEAd
rEAd
InPut
diSPL
Out.MA
Out.U
JbuS
rELAY
tor
Pr.diS
About
or
Validation /
Vertical move
SECU
S