Design and specifications
Page 55
Factory default
12 V/24 V
Min.
12 V/24 V
Max.
12 V/24 V
Switch-on voltage
12.6 V/25.2 V
12.0 V/24.0 V
13.4 V/25.2 V
Switch-off voltage
14.5 V/29.0 V
13.8 V/27.6 V
14.6 V/29.2 V
Switch-off current
2.0 A/1.0 A
0.5 A/0.25 A
10.0 A/5.0 A
Absorption time
180 min
0 min
300 min
Capacity
1
---
20 Ah
600 Ah
Max. charging duration
48 h
0 h
120 h
Min. charging duration
30 min
30 min
180 min
Switch-on delay
300 sec
2 sec
600 sec
Battery protection
11.0 V/22.0 V
10.5 V/21.0 V
12.5 V/25.0 V
Required start voltage
9 V/18.0 V
Max. “charge now”
voltage
13.4 V/26.8 V
Max. battery voltage
16.0 V/31.5 V
1
Depends on the battery type and application. Larger battery capacities are possible if additional energy
sources are available (e.g. solar power).
2.4.3
EFOY Lithium Battery
factory default
Min.
Max.
Switch-on threshold
(charge level)
20%
5 %
50 %
Switch-off threshold
(charge level)
80 %
50 %
100 %
Battery protection
10 %
5 %
20 %