Description 

               Refer to the illustrations on page 

2

 

1 Nozzle 

2 Mointing 

bracket 

liquid tank with screw cap 

Controller 
4a Wireles remote 

 

5.   Installation 

Refer to the illustrations on page 

2

 of this manual. 

a) Smoke 

liquid 

• 

Unplug the device 

[8]

 before filling the tank 

[3]

• Only use non-inflammable water-based smoke fluid without oil or grease, such as FLN-5 (5 litres) or FLG-5 
(5 litres high density smoke liquid) 
• Non-recommended smoke liquid may damage the machine and void the warranty. 

1.  Unplug the device from the mains 

[8]

.

 

2.  Unscrew the cap from the tank 

[3]

.

 

3.  Carefully pour smoke liquid into the tank (do not overfill it!).

 

4.  Close the screw cap firmly.

 

5.  Gently slide the feeder tube 

[9]

 into the reservoir until the tip touches the bottom.

 

Remark: Do not operate the device when the tank [3] is open. 

b) Fuse 

• 

Only fit or replace a fuse when the device is unplugged from the mains. 

• Replace a blown fuse with a fuse of the same type and rating (see “

8.Technical Specifications

”): 

1.  Unplug the device from the mains 

[8]

2.  Unscrew the fuse holder

 [6] 

at the back with an appropriate screwdriver. 

3.  Remove the old fuse and install a new one. 
4.  Replace the fuse holder 

[6]

 and fasten it with the screwdriver. 

c) Mounting 

the 

device 

Note: 

when mounting the device under an angle, do not fill the tank 

[3]

 completely to avoid spilling liquid from 

the tank into the machine. 
• Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms. 
• The construction to which the device is attached should be able to support 10 times the weight of the device 
for one hour without deformation. 
• The installation must always be secured with a secondary attachment e.g. a safety cable  
• Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified 
technician check the device once a year and once before you bring it into service. 
• Install the device in a location with few passers-by that is inaccessible to unauthorised persons.  
• Overhead mounting requires extensive experience: calculating workload limits, determining the installation 
material to be used… Have the material and the device itself checked regularly. Do not attempt to install the 
device yourself if you lack these qualifications as improper installation may result in injuries. 
• Make sure there is no flammable material within a 50cm radius of the device. 
• Have a qualified electrician carry out the electric connection. 
• Connect the device to the mains with the power plug 

[6]

. Don´t connect it to a dimming pack. 

• The installation has to be approved by an expert before the device is taken into service. 
 

      6.   Use 
      

Refer to the illustrations on page

 2

 of this manual. 

            •  Connect  the  device  to  the  mains

 [6] 

and flick the power switch 

[7]

  at  the  back  of  the  device  to  ON.             

After the warm-up time (approx. 8 minutes) the device is ready for use. The red indicator light 

[4/4a]

 is now lit. 

           • Activate/deactivate the smoke output with the push button 

[4/4a]

           • It may happen that the standby lamp on the controller [4/4a] is off and the smoke emission stops, even while 
you are holding the button. In this case the device is warming up again and will be ready to resume operation in a few 
minutes´ time. This process guarantees an appropriate vaporization temperature and the best smoke emission 
possible. 
 
 