5
EN
Eachbendorchangeofdirectioncausesminorlosses,
whichmustbedeductedfromthedischargeperformance
figuresinaccordancewiththeusualheadlosspractice.
(Roughguide:reducedischargeheightby3feetforeach
90°turn).
Thedischargepipeworkcanbemadefrom3/4"diameter
material.Copper(TypeM),CPVCorPVC.Uselongturn
bendsandnotelbows,elbowsarenotnormallyavailablein
plasticpiping,usetwo45°piecesbacktobacktomakea
90°elbow.
Theconnectiontothesoil-stackorsewerpipeshouldbe
madewithanapprovedwyefitting.Whenindoubtabout
thisprocedurepleasehaveaplumbingcontractorinstall
thisforyou.
7f
ELECTRICAL CONNECTION
Allwiringshouldbeinaccordancewiththeapplicable
electricalcodeinyourterritory.Themaceratingsystem
requiresasingle-phase120-volt,15Amp.supply.When
installedinabathroom,thereceptacleshouldbe40inches
away(inastraightline)fromashowerorbathtub.Connect
onlytoreceptacleprotectedbyagroundfaultcircuit
interrupter(GFCI).
WARNING:
riskofelectricshock-thispumpissuplied
withagroundingconductorandgroundingtype
attachmentplugtoreducetheriskofelectricalshock.
Becertainthatitisconnectedonlytoaproperlygrounded
-typereceptacle.
10
USAGE
ThenormaldomainofapplicationofSANIFLOmacerating
unitsonlyconcernsthedisposalofhumanwaste,toilet
paperandwater.
SANIPACK
®
isdesignedforfamilyuseonlyandcannot
acceptwithoutdamagethedisposalofsanitaryitemssuch
ascondoms,tampons,sanitarypadsandcottonswabs.
CAUTIONARY NOTES:
Do not discharge any acids, alkaloids, solvents
painting, paint strippers, food waste, plastic bags,
metal such as nails, hairpins, wood, building materials,
kitty litter or anything that could halt or damage or
corrode the unit.
Disregarding the above might damage the macerating
unit and shall void your warranty.
Do not hang bleach blocks or hydrochloride cleaners
in the toilet tank. These solutions have been shown
to deteriorate the plastic and neoprene components
of the flush and fill valves, and may cause leaks. In the
event of a power loss do not use the toilet or any other
sanitary fixture connected to the macerating unit since
it will not work until the power is restored.
Thetoiletworksasaconventionalflushingtoiletandneeds
nomaintenanceinnormaluse.However,thereisnothing
wrongwithcleaningoutthemaceratingunitonceayear.
Donotusebleach(Becarefulnottoletwaterenterthe
electricalcordopening).
Themaceratingunitstartsautomaticallyoncethetoiletis
flushedorthebath,shower,handbasin,etc.dischargeand
ceaseoperationoncethecontentshavebeenpumpedaway.
Whenevertheunitisnottobeusedforlongperiodsof
time(vacation,powerfailure,maintenance,etc.)turnoffthe
watersupplytothetankandflushtheunittoevacuatethe
water.Noleakageintothebowlshouldeverbepermitted
fromthetank.
Inareas,whicharepronetofreezing,thetotalsystemmust
beproperlywinterized.Thisincludesthedrainingofall
pipes,thetoilettankandbowlandthemaceratingtank.
11
CARE OF YOUR SANIPACK
®
Inordertoremovescaleandcleanthemaceratorandthe
bowl,useSaniflo’sdescaler.
•Disconnectthepower,
•Pouranamountofdescalentinthebowlandflushtoilet,
•Leaveittostandfor1or2hours,
•Re-connectthepower,
•Rinsebyoperatingtheflushingsystemtwice.
Carryouttheoperationonceevery3monthsonaverage,
butthefrequencymayneedtobechangeddependingon
thehardnessofthewater.
Themaceratingsystemissimpletowinterize.Pourajugof
plumbers’anti-freezeintothetankandflushthetoilet.This
willcausethemaceratingunittoactivateandallremaining
waterwillbereplacedbyplumber’santi-freeze.Noparts
orlabourarewarrantedwhenabreakdownoccursdueto
freezing.
Ensurethattherearenofaucetsleftopen.Dropswill
eventuallyfillupthepumpandtheresultantrepeated
start-stopofthemotormayheatuptosuchanextent,that
thethermaloverloadswitchmayeventuallyoperateand
automaticallystopthemotor,thuspossiblycausinga
flood.
12
FAULT-FINDING CHART
REMEDIES
•Askanapprovedrepair
agenttointervene.
•Checktheinstallation
upstream.
•Cleanorreplacethe
non-returnvalve.
•Callaserviceengineerto
clearthegrille.
•Cleartheairinlet.
•Checktheinstallation.
•Callaserviceengineerto
unblocktheunit.
•Restoretheelectrical
supply.
•Callaserviceengineerto
inspectthemotor.
•Callaserviceengineerto
inspectthemotor.
•Callaserviceengineerto
removetheforeignobject
fromtheunit.
•Callaserviceengineerto
inspectthemotor.
•Checktheinstallation
•Callaserviceengineer
toremovetheforeign
object.
PROBABLECAUSES
• An object is blocking the
blades.
• The unit has been
running for too long.
• The WC cistern or taps are
running/leaking.
• The external non-return
valve is faulty.
• The inner grille (4) is
clogged.
• The air inlet is clogged up.
• The length or height of
the installation is over
specification, or there are
too many bends/elbows.
• The pump itself is
blocked.
• The electrical supply is
switched off.
• The electrical supply is
faulty.
• The motor is defective.
• A foreign object has
entered into the grille via
the WC pan.
• The capacitor or motor is
defective.
• Shower installed too low
as compared with the
macerator unit
• Hinged side inlet discs
clogged up
SYMPTOM
•Theunitstops.
•Themotorintermittently
activates.
•ThewaterintheWCpan
goesdownveryslowly.
•Themotoroperates
normally,butcontinues
torunforalongtime.
•Themotordoesnot
activate.
•Themotoremitsarattling
orcrunchingsound.
•Themotorhums,butdoes
notturn.
•Cloudywatercomesup
intotheshowerbasin
(unitswithsideinlets).
Warning-Alwaysdisconnecttheelectricitysupplybeforeattempting
anyworkontheSANIFLO
®
For the most part, any inconsistencies in the
operation of the unit will be minor and easily rectified. Please
refer to the chart below. If the problem cannot easily be
remedied in this way, please call our Service Organisation.
10514 126 SANIPACK US 062012.indd 5