STANDARDS
SANICONDENS
®
Mini
conforms to the European directive
89/336/CEE on electrical safety.
8
DISASSEMBLY
If a breakdown occurs, any service on the unit should be
carried out by a qualified engineer. In particular the
replacement of the power cable.
Disconnect the electrical supply before carrying out
work on the unit.
9
GUARANTEE
SANICONDENS
®
Mini
SFA is guaranteed for 2 years for
parts and labour, subject to correct installation and use of
the unit.
11
TROUBLESHOOTING
10
Disconnect the electrical supply before carrying out any work.
FAULT DETECTED
• The pump does not start
• The pump does not lift
PROBABLE CAUSES
• The pump is not
connected to the power
supply
• Power cut
• Float blocked
• Condensates inlet pipe
blocked
• Non-return valve blocked
• Discharge pipe blocked
ACTION NEEDED
• Plug in the unit.
•
Check the mains voltage.
• Clean the SANICONDENS
®
Mini tank.
• Clean the SANICONDENS
®
Mini inlet pipe.
• Clean the valve.
• Clean the discharge pipe.
INSTRUCTIONS RESERVED SOLELY FOR
QUALIFIED PROFESSIONALS
INSTRUCTIONS INTENDED SOLELY FOR
QUALIFIED PROFESSIONALS
7043 NOTICE N°135 13/06/07 13:41 Page 7