SF SFTHCPH022WFC Скачать руководство пользователя страница 42

38

Advanced Setup Table

cont. next page

 

Df = Factory Default Setting

Step# Description 

Pg# Range 

Df

Available Modes 

23 

Heat/Cool/Auto/Off,  

Heat/ 

   

 Heat/Cool/Off, 

Cool/ 

 

 

 

Heat/Off, Cool/Off 

Auto/Off

Backlight 

17  On, Off 

Off

Backlight Level 

17 

Off thru 7 levels of brightness

 

Level 5

Night Dimmer 

17  On/Off 

Off

Night Dimmer Brightness 

17 

Off thru 7 levels of brightness

 

2 (20%)

Night Dimmer Start Time 

17  12A-12A 

8:00P

Night Dimmer Stop Time 

17  12A-12A 

6:00A

Current Service Filter Runtime Hours  21  0-1999 Hours 

0

Current Service Filter Calendar Days  21  0-720 Days 

0

10 

Current Override Hours 

23  0-1999 Hours 

0

11 

Current UV Lamp Calendar Days 

22  0-720 Days 

0

12 

Current Humidifier Calendar Days 

22  0-720 Days 

0

13 

Set Service Filter Runtime Hours 

21  0-1950 hours 

0

14 

Set Service Filter Calendar Days 

22  0-720 Days 

0

15 

Set UV Lamp Calendar Days 

22  0-720 Days 

0

16 

Set Humidifier Calendar Days 

22  0-720 Days 

0

17 

Language 

17  English, Espanol, Francais  English

18 

Scrolling Method 

18 

“L-R Slow, L-R Fast, Word L-R   “Whole 

 

 

 

Slow, Word L-R Fast,  

Words

 

 

 

Whole Word L Slow, Whole  

Center 

 

 

 

Word R Slow, Whole Word Ctr.   Fast” 

 

 

 

Fast, Whole Word Ctr. Slow” 

19 

Setpoint Limits 

24  0 - 3 

0

20 

Max Heat Setpoint 

24  35 - 99 Degrees 

74

21 

Min Cool Setpoint 

24  35 - 99 Degrees 

70

22 

Cycles Per Hour 

24  No Limit, 2, 3, 4, 5, 6 

6

23 

Compressor Minimum Off Minutes 

24  0, 3, 5 Minutes 

5

24 

Min. Heat/Cool Setpoint Difference 

24  0 - 6 Degrees 

2

25 

Number of Heat Stages    

24  0 - 2 

2

26 

Number of Cool Stages 

24  0 - 2 

1

27 

Number Of Compressor Stages 

24  1, 2 

1

28 

Number of Aux Stages 

24  0, 1, 2 

0

29 

1st Stage Deadband 

25  1 - 6 Degrees 

2

30 

Wired Sensor Type  

27  Remote, Supply 

Remote

Содержание SFTHCPH022WFC

Страница 1: ...Premier Series Digital Thermostat Non Programmable with Humidity Control Owner s Manual and Installation Instructions COMMERCIAL model SFTHCPH022WFC...

Страница 2: ...ally firmware updates are released by the manufacturer to add features and or performance enhancements This manual was produced reflecting the most current firmware feature set at the time of publicat...

Страница 3: ...fore heating is turned on without regard to deadband Humidify To increase the amount of moisture in the air Icon The word or symbol that appears on the thermostat display Mode The current operating co...

Страница 4: ...18 Emergency Heat 18 RF Module 19 Wi Fi Module 20 System Runtimes 21 INSTALLER SETUP Program Mode Operation 23 Programming Fan Operation 25 Humidification Dehumidification 26 Dry Contact Operation 27...

Страница 5: ...Know Your Thermostat Optional WiFi Module Backlit Scrolling Display Backlit LCD Display Heat or Cool Demand Indicator Red Heat Green Cool Backlit Cooler Warmer Buttons Setup Buttons Behind Door Overri...

Страница 6: ...2 Get To Know Your Thermostat Setup Buttons...

Страница 7: ...ime 3 Mode Indicators Selects the operational mode of the equipment HEAT Indicates the heating mode COOL Indicates the air conditioning mode HEAT COOL Indicates the system will automatically change ov...

Страница 8: ...ighest and lowest temperatures for the day 7 Wi Fi icons One dot indicates the thermostat recognizes the wireless module The full icon indicates the thermostat is currently connected to the Local acce...

Страница 9: ...es 11 AuxHeat icon Indicates 2nd stage electric strip heat is being used when the thermostat is programmed for Heat Pump operation Only the Aux icon will appear during Cool to Dehumidify to indicate R...

Страница 10: ...the SET CLOCK button to confirm settings NOTE To adjust the time by hours press and hold the FAN button while pressing the WARMER or COOLER buttons Selecting the Heat or Cool Mode Select mode by pres...

Страница 11: ...verride Button Unoccupied Operation During programmed unoccupied periods pressing the OVERRIDE button will force the thermostat into Occupied 1 setting for 30 minutes Each press of the OVERRIDE button...

Страница 12: ...Setup step 26 selects the use of the wired temperature sensor Viewing the Indoor Humidity Sensor IMPORTANT Allow at least 2 minutes after the thermostat is powered on for the humidity to read correctl...

Страница 13: ...f the power to the Heating Air Conditioning system at the main fuse panel Most residential systems have a separate breaker for disconnecting power to the furnace Remove the cover of the old thermostat...

Страница 14: ...e from the Install on the old thermostat Function new thermostat terminal marked connector marked G or F Fan G Y1 Y Cooling Y1 W1 W Heating W1 0 B Rh R M Vr A Power R C Common C O B Rev Valve W1 O B W...

Страница 15: ...Outdoor sensor SENSOR connections REMOTE Remote sensor SENSOR connections DRY Dry Contact CONTACT connections IMPORTANT This thermostat requires both R 24 VAC Return and C 24 VAC Common be connected t...

Страница 16: ...sen the thermostat will energize the fan in heating 2 When GAS EL or HP is set for HP This switch GAS or ELEC defines the Aux Heat type When GAS is chosen the auxiliary heat will not be allowed to run...

Страница 17: ...ntial Commercial 1 Stage Cooling with 1 stage Electric Heat 5 Wire 1 Stage Cooling 1 Stage Heat 24VAC Power 24VAC Common 1st Stage Heat 1st Stage Cool Fan Residential Commercial 2 Stage Cooling with 3...

Страница 18: ...Cool or Heat G Fan Setup Step 24 is set to 2 Number of Compressor Stages Residential Commercial Heat Pump with O Reversing Valve 6 Wire 1 Stage Cooling 2 Stage Heat R 24VAC Power C 24VAC Common W1 O...

Страница 19: ...rol such as a sprinkler system DEHUM Dehumidification Terminal on Equipment Humidification System R G W1 O B W2 Y1 Y2 W3 DEHUM HUM C AUX REMOTE SENSOR OUTDOOR SENSOR DRY CONTACT R G W1 O B W2 Y1 Y2 W3...

Страница 20: ...display will read NOTHING ON Next Press WARMER to turn on and cycle up through the heating stages Press COOLER to turn the heating stages off Press MODE to exit Press COOLER to turn on and cycle down...

Страница 21: ...etween Off and seven levels of brightness Night Dimmer setup step 4 Selecting On allows for automatic dimming of the display at night Night Dimmer Brightness setup step 5 The nighttime backlight can b...

Страница 22: ...ll remove icons Keep pressing DISPLAY to make icons reappear Press and hold DISPLAY for 5 seconds to view a name and phone number to call for service Any removed icons will be displayed temporarily wh...

Страница 23: ...many of the wireless devices this status includes Battery Level Signal Strength and LastTime Updated If there is an optional wireless module installed the ACCESSORY SETUP button allows the user to li...

Страница 24: ...screens listed below a Wi Fi status connecting connected etc b Signal strength c Access point name d IP address e MAC address f Skyport status connecting connected with etc g Local API status Enabled...

Страница 25: ...rs of fan runtime in the Heating mode Cooling mode and in stand alone Fan operation Press FAN to reset Current Service Filter Calendar Days Setup Step 9 This counter displays the total number of calen...

Страница 26: ...Days setup step 15 This timer allows the user to specify the number of calendar days the UV Lamp will operate before the Replace UV Lamp alert will be displayed Press COOLER continuously until 0 appe...

Страница 27: ...nd Also allows the manual selection of HEAT only or COOL only and OFF Heat and Cool Allows the thermostat to turn on heating or cooling depending on which one has been manually selected Auto Changeove...

Страница 28: ...mple at a setting of 6 cycles per hour the HVAC unit will only be allowed to energize once every 10 minutes The Cycles Per Hour limit may be overridden and reset by pressing the WARMER or COOLER butto...

Страница 29: ...ees For example if the heat setpoint is 68 and the 1st Stage deadband is set to 2 degrees the room temperature will need to reach 66 before the heat turns on Fan Off Delay in Seconds setup step 40 Thi...

Страница 30: ...demand 0 20 Reheat Operation With CoolTo Dehumidify Setup Step 38 Specifies if electric strip heat is allowed to turn on during a Cool to Dehumidify demand to help maintain desired room temperature Th...

Страница 31: ...o the prior mode setpoints for a limited amount of time This setting is commonly used to emulate the function of a twist timer FDD If FDD is selected when the dry contact is active EQUIPMENT FAULT wil...

Страница 32: ...all linked wireless remote sensors AverageThermostat and Wired Remote Averages the temperatures of the wired remote sensor and the thermostat Average All Sensors Averages the temperatures of the wire...

Страница 33: ...settings of the thermostat in order to reduce energy usage on demand This is known as Automated Demand Response ADR You must register to participate in a utility sponsored program if offered by your l...

Страница 34: ...to the energy provider s signals It also sets operational parameters for the thermostat The left column of the ADR configuration page allows or prevents access by the utility Here communication with t...

Страница 35: ...Installer Setup Automated Demand Response 31 Selecting the Overview tab of the ADR page will cause a summary of ADR events to be displayed Office Configuration...

Страница 36: ...tatic Setpoints will set the heat and cool setpoints to the values specified in setup steps 56 and 57 Event Max Cool Setpoint setup step 54 Event Min Heat Setpoint setup step 55 Specifies the range of...

Страница 37: ...t can be automatically raised by 1 to 15 degrees DISPLAY INDICATIONS WHEN AN ADR EVENT IS HAPPENING After setting your desired values for use during an ADR event the scrolling display will give a litt...

Страница 38: ...utton press the WARMER and COOLER buttons together The icon will appear on the display then release the buttons Press all three buttons in the order outlined above for keypad lockout To unlock the key...

Страница 39: ...permanently lost 1 Press and hold SETUP for 10 seconds All icons will appear on the display Keep pressing the SETUP button until you see this screen 2 After all the icons appear release SETUP Press an...

Страница 40: ...ed for use by a qualified technician See page 14 for more detailed instructions Technician Setup contains the following options View the version number of the thermostat View the Dip Switch equipment...

Страница 41: ...tpoint Limits page 22 SYMPTOM The heating does not attempt to turn on CAUSE The heating setpoint is set too low REMEDY Raise the heating setpoint or raise the heating set point limit See Setpoint Limi...

Страница 42: ...0 13 Set Service Filter Runtime Hours 21 0 1950 hours 0 14 Set Service Filter Calendar Days 22 0 720 Days 0 15 Set UV Lamp Calendar Days 22 0 720 Days 0 16 Set Humidifier Calendar Days 22 0 720 Days...

Страница 43: ...rees 2 39 Reheat Operation W CoolTo Dehum 29 On Off Off 40 Fan Off Delay 25 0 120 Seconds 0 41 F C 28 Fahrenheit F Celsius C F 42 Dry Contact Polarity 27 Open Closed Open 43 Dry Contact Use 27 Condens...

Страница 44: ...WHATSOEVER ALL WORK UNDERTHETERMS OFTHIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME ASTHEIR WARRANTY PERIOD ONLYTHE REMAININGTIM...

Страница 45: ...ture Adjustment Range Accuracy 10 RH from 30 70 RH 50 90 F Humidity Wire Size Deadband Operating Storage Ambient Conditions Compliance Dimensions Shipping Weight This equipment has been tested and fou...

Страница 46: ...Printed on recycled paper P N 88 1258 Rev 1 05 18 Patent Pending...

Отзывы: