34
English
4.2 Operating modes
The device can be used in two different modes:
z
Measurement
> see chapter 5
z
Adjustment
> see chapter 6
4.3 Measuring range
The device operates with a single measuring range, but two different units of measurement (parts per
million [ppm], percent by volume [vol.%]). The device automatically switches between the different
units of measurement.
Conversion: 10,000 ppm = 1 vol.%
Indication of
measurement values in
Limits
Resolution
ppm
0 – 100 ppm
5 ppm
ppm
> 100 – 2,000 ppm
50 ppm
percent by volume
CH
4
, C
3
H
8
: > 2,000 – 22,000 ppm (0.2 – 2.2 vol.%)
0.2 vol.%
H
2
:
> 2,000 – 10,000 ppm (0.2 – 1.0 vol.%)
Содержание Snooper Mini
Страница 1: ...SNOOPER mini...