19
4 Electroacoustic water leak detection
Electroacoustic water leak detection
To deactivate the
AC 06
re-
lease the
rotary regulator
or
press the
microphone key
again.
If the
AC 06
does not go off
when you release the rotary
regulator, the function of the
rotary regulator has been
changed. In this case press
the rotary regulator again.
Place the test rod at the next
measurement location and
proceed as above.
The previously measured
value will now appear in the
small digital display for com-
parison purposes.