5
Connecting MOVIGEAR
®
drive units
Electrical installation
5.5
Connecting MOVIGEAR
®
drive units
WARNING
No safe disconnection of the MOVIGEAR
®
drive unit.
Severe or fatal injuries.
• Do not use the 24 V output (terminals 5, 15,) for safety-related applications with
MOVIGEAR
®
drive units.
• You may only jumper the STO input with 24 V when the MOVIGEAR
®
drive unit
need not fulfill any safety function.
18014400994276107
[1] See documentation of the SNI controller
[2] See chapter "Terminal assignment"
[3] DC 24 V output
[4] Sensor supply input, the sensor supply voltage is then available at the optional plug connec-
tor for sensor inputs
[5] Looping of the sensor supply input
[6] See chapter "Optional plug connector assignment"
MOVIGEAR SNI-B
®
2 STO
̶ IN
1 STO + IN
12 STO
̶ OUT
11 STO + OUT
15 0V24_O
5 24V_O
13 + 24V_SEN
3 + 24V_SEN
4 0V 24V_SEN
14 0V 24V_SEN
[6] Connection to
the optional
plug connector
X5131
for sensor inputs
L1
L2
L3
[1] SNI controller connection
Line terminals [2]
Control
terminals [2]
[3]
[5]
[4]
X2
X7
Содержание movigear sni-b