8
Description of command PCB parameters
Parameters
Firmware com-
mand level
index 9701.30,
9701.31
The parameter indicates the part number of the firmware used in the command PCB.
Firmware SNI
interface
index 9701.36,
9701.37
The parameter indicates the program version of the firmware used for SNI communica-
tion.
Application option
type index 10453.1
The parameter indicates the designation of the application option inserted in the appli-
cation slot.
Command pcb parameters \ display values \ address settings
MAC address
index 8995.0 –
8996.0
The parameter indicates the MAC address of the MOVIGEAR
®
SNI drive unit.
8.4.2
Setpoints/ramp generators
Command PCB parameters \ setpoints/ramp generators \ setpoints
Setpoint n_f1
index 10096.35
Use this parameter to set setpoint "n_f1".
• Unit: [rpm]
• Setting range: 0 – 1500 – 2000 rpm
The setpoint "n_f1" is valid if
• local mode is active (DIP switch S2/3 = "1") and a "0" signal is present at digital input
DI03 "f1/f2".
Setpoint n_f2
index 10096.36
Use this parameter to set setpoint "n_f2".
• Unit: [rpm]
• Setting range: 0 – 200 – 2000 rpm
The setpoint n_f2 is valid if
• local mode is active (DIP switch S2/3 = "1") and a "1" signal is present at digital input
DI03 "f1/f2".