5
Mechanical Installation
Central opening/closing mechanism
24
Operating Instructions – MOVIFIT
®
SC
5.4
Central opening/closing mechanism
5.4.1
Operation
A socket wrench (SW8) is required for the central retaining screw.
STOP!
If the torque is too high, the central opening/closing mechanism can be destroyed.
• It is essential that you do not exceed a maximum torque of 7 Nm when closing.
The enclosure specified in the technical data only applies when a unit is mounted
correctly. The MOVIFIT
®
may be damaged by moisture or dust when the EBOX is
removed from the ABOX.
• Protect ABOX and EBOX for when the unit is open.
Open
Close
58936AXX
61071AXX
EBOX
ABOX
1.
ABOX
2.
EBOX
EBOX
ABOX
1.
ABOX
2.
EBOX
max.
7 Nm!