1.

 

SAFETY

 

PRECAUTIONS.

 

SAFETY  RULES

 

 

CAUTION

 

RISK

 

OF

 

ELECTRIC

 

SHOCK

 

This

 

tester

 

has

 

been

 

designed

 

with

 

your

 

safety

 

in

 

mind.

 

However,

 

no

 

design

 

can

 

completely

 

protect

 

against

 

incorrect

 

use.

 

Electrical

 

circuits

 

can

 

be

 

dangerous

 

and/or

 

lethal

 

when

 

lack

 

of

 

caution

 

and/or

 

poor

 

safety

 

practices

 

are

 

used.

 

 

Do

 

not

 

carry

 

out

 

field

 

measurements

 

on

 

either

 

the

 

power

 

system

 

grounding,

 

during

 

periods

 

of

 

forecast

 

lightning

 

activity,

 

or

 

any

 

non

 

insulated

 

system

 

or

 

non

 

insulated

 

circuit.

 

In

 

the

 

event

 

that

 

lightning

 

occurs,

 

stop

 

all

 

testing

 

and

 

isolate

 

and

 

remove

 

any

 

temporarily

 

installed

 

test

 

spikes

 

or

 

test

 

leads.

 

Preparations

 

for

 

testing

 

of

 

power

 

system

 

grounding

 

or

 

close

 

to

 

it

 

can

 

leave

 

personnel

 

vulnerable

 

to

 

exposure

 

caused

 

by

 

faults

 

at

 

or

 

fed

 

from

 

the

 

system

 

under

 

test,

 

transferred

 

potentials

 

from

 

remote

 

test

 

grounds,

 

and

 

inadvertent

 

line

 

energizations.

 

Always

 

insulate

 

the

 

device

 

under

 

test.

 

 

While

 

the

 

probability

 

of

 

the

 

occurrence

 

of

 

one

 

of

 

these

 

events

 

is

 

low,

 

personnel

 

safety

 

will,

 

nevertheless,

 

be

 

enhanced

 

by

 

the

 

following:

 

 

When

 

working

 

near

 

high

 

tension

 

systems

 

rubber

 

gloves

 

and

 

shoes

 

should

 

be

 

worn.

 

Work

 

on

 

clean,

 

dry

 

crushed

 

rock

 

or

 

an

 

insulating

 

blanket.

 

Avoid

 

bare

 

hand

 

to

 

hand

 

contact

 

between

 

the

 

tester

 

and

 

extended

 

test

 

leads.

 

 

When

 

using

 

the

 

tester

 

with

 

test

 

leads,

 

ensure

 

that

 

they

 

are

 

safe

 

and

 

properly

 

authorized

 

Disconnect

 

the

 

tester

 

from

 

any

 

external

 

circuit

 

when

 

checking

 

or

 

changing

 

the

 

Fuse

 

and/or

 

batteries.

 

 

CAUTION

 

READ

 

THE

 

MANUAL

 

Follow

 

the

 

instructions

 

in

 

the

 

Manual

 

for

 

every

 

measurement.

 

Read

 

and

 

understand

 

the

 

general

 

instructions

 

before

 

attempting

 

to

 

use

 

this

 

tester

 

-5-

Содержание 6213A-IN

Страница 1: ...itales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com Medidores de aislamiento Megohmetros Digitales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com 6213A IN DIGITAL VAR...

Страница 2: ...ingles www viaindustrial com TABLE OF CONTENTS Index 2 Front Panel Layout 3 Inside Lid Instructions 4 Safety precautions 5 8 Overview 9 Features 10 Connections 11 Specifications 12 Functions 13 15 Sp...

Страница 3: ...AYSREADUSER SMANUALBEFOREOPERATINGTHISINSTRUMENT Useonlyonde energisedandisolated disconnectedsystem DONOTPROCEEDIFVOLTAGEPRESENT Checktestleadsfordefects Ifanycracksordamages replacewithnewtest leads...

Страница 4: ...AR WARNING Thisinstrumentshould notbeusedinexplosive orinflammable environments although thereisunlikelytobea firehazardfromthe instrumentitself However arcingin faultyinsulation sparkingcausedwhen ma...

Страница 5: ...or test leads Preparations for testing of power system grounding or close to it can leave personnel vulnerable to exposure caused by faults at or fed from the system under test transferred potentials...

Страница 6: ...hey were new Always disconnect the test leads when changing the batteries by removing the cover which give access to the batteries Always double check the lead connections before making any measuremen...

Страница 7: ...warning features should your Variable High Voltage Digital Insulation Meter be connected to a live system 1 3 Never open your Variable High Voltage Digital Insulation Meter except for battery replacem...

Страница 8: ...gaOhmios 6213 IN SEW manual ingles www viaindustrial com 1 7 Your Variable High Voltage Digital Insulation Meter has a live circuit warning beeper If It is connected to a live circuit a rapid pulsatin...

Страница 9: ...his bar graph is showing voltage output during the first 30 seconds of the test or during automatic discharge of circuits During the automatic discharge of the circuit tested the bar graph displays th...

Страница 10: ...6 5KV 7KV 7 5KV 8KV 8 5KV 9KV 9 5KV 10KV Calculate Dielectric Absorption Ratio DAR Automatically Calculate Polarization Index PI Automatically Insulation resistance Auto Ranging on all ranges TM Bar g...

Страница 11: ...Ohmios 6213 IN SEW manual ingles www viaindustrial com Medidores de aislamiento Megohmetros Digitales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com 4 CONNECTIONS INSULATOR HV 10kV VAR...

Страница 12: ...5KV 5KV 10KV Measuring Range 800K 500G AUTO RANGING Accuracy 5 2 digits Power 8 x 1 5V Alkaline batteries Output Power Limit 1W Voltage Regulation Selected Voltage 20 5 of nominal value unless curren...

Страница 13: ...test voltage press 10KV button 2 6 3 Insulation Resistance Measurement 5KVdc To Select 5KVdc test voltage press 5KV button 4 6 4 Insulation Resistance Measurement 2 5KVdc To Select 2 5KVdc test volta...

Страница 14: ...certain time or to make comparison See Special Features for more Timer Functions 6 11 STOP test To stop the test in progress press the TEST button 3 The test will immediately stop discharge and the i...

Страница 15: ...ed by a one second long beep accompanied by the HOLD message on the display DO NOT REMOVE LEADS UNTIL THE HOLD MESSAGE APPEARS ON THE DISPLAY 6 15 Replace Battery Warning Indicator If the battery ener...

Страница 16: ...Polarization Index The Polarization Index or PI is the ratio of the Insulation Resistance measured at 10 Minutes divided per the Insulation Resistance measured at 1 Minute 10 Minutes after starting a...

Страница 17: ...t any time before during and after the test It s your responsibility to ensure proper contact of the leads at all times Once a test is finished the testers will automatically discharge capacitive or i...

Страница 18: ...6213 IN SEW manual ingles www viaindustrial com 8 PREPARATION FOR MEASUREMENT 8 1 Before testing always check the following At Power ON read the display to make sure the Replace Battery message is no...

Страница 19: ...ng care to observe correct polarity Replace battery cover 9 2 Cleaning Storage Periodically wipe the case with a damp cloth and detergent Do not use abrasives or solvents If the meter is not to be use...

Страница 20: ...are not live before commencing testing Secure both test leads properly to the insulation to test and use guard lead to collect surface leakage Good contacts are necessary to avoid flashing at high vol...

Страница 21: ...surface of the insulator is too high and therefore the insulator may require cleaning 4 Should your insulator require cleaning follow the procedures recommended by it s manufacturer 5 For Final Test a...

Страница 22: ...r characteristics may deteriorate due to many factors Their material properties may deteriorate with time and frequency use as well as stress put on to them One of the factor we will be testing is the...

Страница 23: ...ormers are painted or dipped with insulating varnish large power transformers are painted with High Voltage insulating paint of very high specifications Many Applications uses insulating material to p...

Страница 24: ...arranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way so as in our sole judgement to injure their stability or reliability or which have...

Отзывы: