Operating Instructions – MOVITRANS® THM20C / THM20E Pick-Ups
29
6
Technical data of THM20C
Technical Data
6.1.3
Transmittable power
With the THM20C pick-up, a difference is made between the peak power P
1
(P
1
> P
N
;
t
1
< 150 s) and the minimum power P
2
(P
2
< P
N
).
During project planning, you must determine the minimum power P
2
of the THM20C
pick-up and the duty factor D:
Line cable geometry/distance x between
Line cable and THM20C pick-up
Transmittable power
Line cable current = 60 A
[mm]
Peak power P
1
[W]
Nominal power P
N
[W]
Straight / 15
1100
800
Straight / 19
1100
800
Straight / 24
1100
800
Straight / 29
1000
700
Straight / 39
700
500
Inner curve with r = 750 mm / 19
1100
800
Outer curve with r = 750 mm / 19
1100
800
Vertical curve with
α
= 7° / 19
1100
800
5048901771
t
1
= cyclic duration factor for peak power P
1
> P
N
Maximum cyclic duration factor for peak power t
1
< 150 s
T = cycle duration
5048905355
D
t
T
=
1
t [s]
P
1
t
1
P
2
P
N
P
T
INFORMATION
The following values are based on a distance of x = 19 mm between the line cable and
the THM20C pick-up. If the actual distance is different, make sure that you do not ex-
ceed the peak power P
1
that is listed in the "Transmittable power" table.