6
Electrical installation
Hybrid cable connection
Manual – PROFINET IO Interfaces, Field Distributors
71
6.9.3
Hybrid cable between MFZ.9. field distributor and AC motors
The following figure shows the hybrid cable for connecting the AC motor
part number
08184380
.
MFZ.9
+
18205192331
The following table shows the terminal assignment of the hybrid cable in the motor ter-
minal box and in the field distributor:
Terminal assignment
Motor ter-
minal
Wire color/
hybrid cable designation
Field distributor terminal
Motor 1
connection
Motor 2
connection
Motor 3
connection
U1
Black/U1
X4_1/4
X4_2/4
X4_3/4
V1
Black/V1
X4_1/5
X4_2/5
X4_3/5
W1
Black/W1
X4_1/6
X4_2/6
X4_3/6
4a
Red/13
X4_1/1
X4_2/1
X4_3/1
3a
White/14
X4_1/2
X4_2/2
X4_3/2
5a
Blue/15
X4_1/3
X4_2/3
X4_3/3
1a
Black/1
X6_1/3
X6_2/3
X6_3/3
2a
Black/2
X6_1/7
X6_2/7
X6_3/7
PE terminal
Green/yellow
+ shield end (inner shield)
y
1)
y
1)
y
1)
1) PE connection in the housing
INFORMATION
Attach the outer shield of the cable to the housing of the motor terminal box using an
EMC metal cable gland.
22870857/EN – 12/2016