background image

MOVIDRIVE

®

 DC Link Connection 

15

4.1

DC link connection without regenerative power supply unit

Circuit type A

02207BEN

Fig. 3: DC link connection in circuit type A

K11

(AC-3)

U1

U1

V1

V1

W1

W1

U2

U2

V2

V2

W2

W2

X1:

X1:

X4:

X4:

X2:

X2:

X3:

X3:

y

y

y

y

y

y

y

y

y

y

L1

L1

L2

L2

L3

L3

L1'

L1'

L2'

L2'

L3'

L3'

L1

L2

L3

PE

L1 L2 L3

L1 L2 L3

U V W

U V W

+R -R PE

+R -R PE

1

2

3

1

2

3

7 8

7 8

4

5

6

4

5

6

8 9

8 9

ND...

ND...

y

BW...

M

3 phase

M

3 phase

DC link connection

max. length 2 m (6.6 ft)

NF... input filter

NF... input filter

2nd MOVIDRIVE

®

1st MOVIDRIVE

®

PE

PE

+V

DC

+V

DC

-V

DC

-V

DC

An incorrect DC link connection

(polarity reversal, ground fault)

will destroy the connected units!

F16 operates

K11

Содержание Movidrive DC Link

Страница 1: ...MOVIDRIVE DC Link Connection Edition 09 2001 Manual 0918 2918 EN...

Страница 2: ......

Страница 3: ...k connection 6 3 Project Planning 8 3 1 DC link connection without regenerative power supply unit 8 3 2 DC link connection with regenerative power supply unit 11 4 Installation 15 4 1 DC link connecti...

Страница 4: ...4 MOVIDRIVE DC Link Connection Safety and warning instructions Designated use...

Страница 5: ...MOVIDRIVE DC Link Connection 5 Application environment Waste disposal...

Страница 6: ...6 MOVIDRIVE DC Link Connection 2 1 Two types of DC link connection 1 Without regenerative power supply unit Circuit type A 05242AXX Fig 1 Circuit type A 3 x 380 500 VAC A ND ND NF NF BW...

Страница 7: ...MOVIDRIVE DC Link Connection 7 Circuit type B 2 With regenerative power supply unit 05243AXX Fig 2 Circuit type B 3 x 380 500 VAC B ND NF BW...

Страница 8: ...4 0150 503 4 0220 503 4 0300 503 4 0150 503 4 0220 503 4 0300 503 4 0370 503 4 0220 503 4 0300 503 4 0370 503 4 0450 503 4 0220 503 4 0300 503 4 0370 503 4 0450 503 4 0550 503 4 0300 503 4 0370 503 4...

Страница 9: ...3 4 0015 5A3 4 0110 5A3 4 0300 503 4 0015 5A3 4 0150 503 4 0370 503 4 0015 5A3 4 0150 503 4 0450 503 4 0015 5A3 4 0220 503 4 0550 503 4 0015 5A3 4 0300 503 4 0750 503 4 0015 5A3 4 0370 503 4 Size MOVI...

Страница 10: ...4 mm2 AWG10 conductor end sleeve DIN 46228 Screw and washer assembly M4 with terminal clip 4 mm2 AWG10 conductor end sleeve DIN 46228 6 mm2 AWG10 crimp cable lug DIN 46234 MOVIDRIVE 0150 0220 0300 03...

Страница 11: ...MOVIDRIVE DC Link Connection 11 3 2 DC link connection with regenerative power supply unit Project planning notes DCL...

Страница 12: ...12 MOVIDRIVE DC Link Connection Sample points score calculation N N...

Страница 13: ...MOVIDRIVE DC Link Connection 13 Mains fuses and supply system lead DC link connection and DC link fuses DCL DCL DC...

Страница 14: ...lor black 25 mm2 AWG4 l 5 m 16 5 in 1 pce PVC single core cable H07V K Color black 50 mm2 AWG0 l 5 m 16 5 in 1 pce PVC single core cable H07V K Color red 4 mm2 AWG10 l 5 m 16 5 in 1 pce PVC single cor...

Страница 15: ...X2 X3 X3 y y y y y y y y y y L1 L1 L2 L2 L3 L3 L1 L1 L2 L2 L3 L3 L1 L2 L3 PE L1 L2 L3 L1 L2 L3 U V W U V W R R PE R R PE 1 2 3 1 2 3 7 8 7 8 4 5 6 4 5 6 8 9 8 9 ND ND y BW M 3phase M 3phase DClinkcon...

Страница 16: ...y y y y L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 U V W U V W R R PE R R PE 1 2 3 1 2 3 7 8 7 8 4 5 6 4 5 6 8 9 8 9 ND y BW L1 L2 L3 PE M 3phase M 3phase DClinkconnection max length 2m 6 6ft NF input filter...

Страница 17: ...L1 L2 L3 24 V bk rd bk rd bk bk rd rd y PE 7d 8d y PE MOVIDRIVE 4 5 6 y y 1 2 3 y y 8 7 1 2 3 R PE PE X1 X4 X2 y 9 8 X3 PE L1 L2 L3 PE U V W R PE max 5 m 16 5 ft An incorrect DC link polar ity revers...

Страница 18: ...18 MOVIDRIVE DC Link Connection DCL 03621BXX Fig 6 Connecting a DCD12A damping module X1 X4 X2 X3 y y y y L1 L2 L3 U U PE Z Z U V W R R PE 1 2 3 7 8 4 5 6 8 9 MOVIDRIVE 0015 5A3 0110 5A3 DCD12A UZ UZ...

Страница 19: ...10 2000...

Страница 20: ...SEW EURODRIVE GmbH Co P O Box 3023 D 76642 Bruchsal Germany Phone 49 7251 75 0 Fax 49 7251 75 1970 http www sew eurodrive com sew sew eurodrive com...