SEW-Eurodrive EDR71 Скачать руководство пользователя страница 5

1

Revision

Motor structure

Revision – EDR..71 – 315, EDRN80 – 315

5

1.2

Motor structure

1.2.1

Functional safety

Drives from SEW‑EURODRIVE are also available with functional safety motor options.
These  options  are  intended  for  implementation  of  safety  functions  in  safety-relevant
applications.

SEW‑EURODRIVE labels a functionally safe motor option at the drive with an FS logo
and  a  2-digit  number  on  the  motor  nameplate.  The  number  is  a  code  that  indicates
which  components  in  the  drive  are  safety-related.  This  allows  to  uniquely  identify  an
available functionally safe motor option via the motor nameplate.

FS logo

Available functionally safe motor option

Decentralized in-

verters

Safety brake

Safety encoders

01

X

02

X

04

X

07

X

X

11

X

X

If the FS logo, e.g. with the code "FS-11" is present on the motor nameplate, the com-
bination of safety encoder and safety brake is available at the motor. If an FS logo is
available, adhere to the information specified in the corresponding documentation.

If the drive bears the FS logo on the nameplate, you must adhere to the information in
the following document:

Addendum to the operating instructions "Safety Encoders and Safety Brakes, AC
Motors DR.., DRN.., DR2.., EDR.., EDRN.. – Functional Safety"

To determine the safety level for systems and machines yourself, refer to the charac-
teristic safety values in chapter Characteristic safety values.

22127909/EN – 07/2018

Содержание EDR71

Страница 1: ... 22127909_0718 Drive Technology Drive Automation System Integration Services Revision Explosion Proof AC Motors EDR 71 315 EDRN80 315 ATEX Edition 07 2018 22127909 EN ...

Страница 2: ...SEW EURODRIVE Driving the world ...

Страница 3: ...e of contents Revision EDR 71 315 EDRN80 315 3 Table of contents 1 Revision 4 1 1 General information 4 1 2 Motor structure 5 1 3 Mechanical installation 6 1 4 Startup 9 1 5 Appendix 10 22127909 EN 07 2018 ...

Страница 4: ...al safety Chapter 4 2 Preliminary work after extended storage periods Chapter 7 1 Before startup Chapter 11 6 Declarations of conformity 1 1 General information 1 1 1 Other applicable documentation Explosion proof EDR EDRN motors The following publications and documents have to be observed as well Wiring diagrams provided with the motor Addendum to the operating instructions Safety Encoders and Sa...

Страница 5: ... nameplate FS logo Available functionally safe motor option Decentralized in verters Safety brake Safety encoders 01 X 02 X 04 X 07 X X 11 X X If the FS logo e g with the code FS 11 is present on the motor nameplate the com bination of safety encoder and safety brake is available at the motor If an FS logo is available adhere to the information specified in the corresponding documentation If the d...

Страница 6: ...on damage Embrittlement of seals Visually inspect seals and look for tears hardening and embrittlement Replace any damaged seals Reduced grease service life If the drives are stored for longer than a year the service life of the bearing grease is reduced due to aging and de oiling of the lubricant Check the condition and usability of the rolling bearings Replace any damaged rolling bearing Reduced...

Страница 7: ...otor Proceed as follows to dry the motor 1 Heat up the motor either using warm air or using an isolation transformer WARNING Risk of crushing due to torque at the motor shaft Severe or fatal injuries Only use warm air for drying DR motors with rotor designation J Do not use an isolation transformer for drying DR motors with rotor designation J With warm air 1 DR motors with rotor designation J may...

Страница 8: ...mer Connection with wiring diagram R72 1 V3 T8 W3 T9 V2 T5 W2 T6 V1 T2 U1 T1 W1 T3 U3 T7 U2 T4 W4 T12 V4 T11 U4 T10 2 2343045259 1 Motor terminal boards 2 Transformer Connection with wiring diagram R76 1 V1 T2 U1 T1 W1 T3 W2 W3 T6 T9 V2 V3 T5 T8 U2 U3 T4 T7 2 2343047179 1 Motor terminal boards 2 Transformer 22127909 EN 07 2018 ...

Страница 9: ... been made correctly The direction of rotation of the motor gearmotor is correct Motor rotating clockwise U V W T1 T2 T3 to L1 L2 L3 All protective covers are installed correctly All motor protection equipment is active and set for the rated motor current There are no other sources of danger Loose elements like keys are appropriately secured The brake is not manually released The set screw of HF o...

Страница 10: ...ing the technical documents Place Date 02 07 2018 Managing Director Innovation Mechatronics Dr Hans Krattenmacher a b Motors of the series EDRS71 EDRE315 Possibly in connection with brake of the series BE Variant 3GD 3G or 3D Designation II3G Ex ec IIB T3 Gc II3G Ex ec IIC T3 Gc II3D Ex tc IIIB T120 C Dc II3D Ex tc IIIB T140 C Dc II3D Ex tc IIIC T120 C Dc II3D Ex tc IIIC T140 C Dc in accordance wi...

Страница 11: ... compiling the technical documents Place Date 02 07 2018 Managing Director Innovation Mechatronics Dr Hans Krattenmacher a b Motors of the series EDRS71 EDRE225 Variant 2GD 2G or 2D Designation II2G Ex eb IIB T3 Gb II2G Ex eb IIC T3 Gb II2G Ex eb IIB T4 Gb II2G Ex eb IIC T4 Gb II2D Ex tb IIIC T120 C Db II2D Ex tb IIIC T140 C Db in accordance with ATEX Directive 2014 34 EU L 96 29 03 2014 309 356 R...

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...SEW EURODRIVE Driving the world SEW EURODRIVE GmbH Co KG Ernst Blickle Str 42 76646 BRUCHSAL GERMANY Tel 49 7251 75 0 Fax 49 7251 75 1970 sew sew eurodrive com www sew eurodrive com ...

Отзывы: