Overhung loads and axial loads
Technical Data
Permitted over-
hung load for
CMP50L
The following figure shows the permitted overhung load at point X.
Permitted over-
hung load for
CMP63S
The following figure shows the permitted overhung load at point X.
58652AXX
0
100
200
300
400
500
600
0
5
10
15
20
25
X [mm]
F
R
[N
]
n = 3000 rpm
n = 4500 rpm
n = 6000 rpm
n = 1500 rpm
58653AXX
0
100
200
300
400
500
600
700
800
0
5
10
15
20
25
30
35
X [mm]
F
R
[N
]
n = 3000 rpm
n = 4500 rpm
n = 6000 rpm
n = 1500 rpm
P
i
f
kVA
Hz
n