14 

Troubleshooting 

Error Codes 

Code 

Action 

- - - 

Re-initialize the system. 

Control system  

malfunction 

Please contact customer service. 

Voltage irregularity 

Please contact customer service. 

Over-load protection 

activated 

Remove weight from desk top until error clears. 

Overheat or power 

supply failure 

Let desk cool down for 10 minutes before using again 

Irregular Hall signal from 

Motor A 

Unplug and re-plug power cord, and reset the desk. If problem  

persists, switch motor cables at the control box and re-initialize. 

Motor A malfunction 

Unplug and re-plug power cord, and re-initialize. If problem persists, 

switch motor cables at the control box and re-initialize. 

Motor B malfunction 

Unplug and re-plug power cord, and re-initialize. If problem persists, 

switch motor cables at the control box and re-initialize. 

Lose connection or, 

irregular Hall signal  

Check all cables and make sure they're connected.  

Switch motor cables at the control box and re-initialize. 

Irregular Hall signal on 

Motor B 

Unplug and re-plug power cord, and re-initialize. If problem persists, 

switch motor cables at the control box and re-initialize. 

Anti-collision protection 

activated 

Remove objects from beneath the desk and re-initialize system. 

Problem 

Action 

Desk does not go up or down and the con-

troller 

does not illuminate 

when any button 

is pressed. 

Check all connections. Make sure power cord is plugged into the con-

trol box and a power outlet. Press any button on the  

controller and make sure it illuminates. Re-initialize the desk.  

Desk does not go up or down and the con-

troller 

illuminates 

when any button is 

pressed.  

Unplug the power cord and re-plug after 10 seconds.  

Re-initialize the desk. If the problem persists, switch motor cables from 

one port to another at control box and re-initialize again. 

Columns do not go up evenly.  

Unplug the power cord and re-plug after 10 seconds.  

Re-initialize the desk. If the problem persists, switch motor cables from 

one port to another at control box and re-initialize again. 

Desk wobbles excessively. 

It is normal that desk moves slightly at standing height when in use. 

Retighten all screws and bolts, and adjust leveling feet to make sure 

table stands level.

 

HOT is displayed on the panel. 

The desk motors are overheated. Stop using the desk for 10 minutes 

and let them cool down.

  

Desk legs are noisy. 

It is normal that desk makes noise when the stages move past each 

other. Apply silicon-based lubricant if it is unusually noisy.

  

Содержание airLIFT OFF65871

Страница 1: ...Dual USB Charger Models OFF65871 2 3 Thank you for choosing Seville Classics We hope that you enjoy your new sit to stand desk Please read through this user guide for parts list instructions frequent...

Страница 2: ...ust a convenient upgrade it s a healthy one Too much sedentary behavior can present a real health risk even for people who are already healthy Simply getting up throughout the day and moving is a grea...

Страница 3: ...s SAFETY INSTRUCTIONS COMPONENT DIAGRAM PARTS LIST ASSEMBLY INSTRUCTIONS Unpack Install Left Leg Install Right Leg Connect Motors Final Steps INITIALIZATION USE INSTRUCTIONS TROUBLESHOOTING WARRANTY I...

Страница 4: ...4...

Страница 5: ...some of it s components When moving or turning the assembled desk grab the legs not the desk top Make sure to assemble on a soft and non abrasive surface to avoid scratches Check all connections and c...

Страница 6: ...6 Component Diagram Tempered Glass Top Foot Legs Foot Drawer Legs Controller...

Страница 7: ...e parts on this list Extra washers are included and some may remain unused after assembly If you re missing parts contact us for replacements at 800 323 5565 or send an email to Support SevilleClassic...

Страница 8: ...the desk Make sure there is a grounded outlet or power strip nearby 110 120V Remove the box lid and remove inner box containing parts Leave the TOP A in the box Layout all components and hardware Exa...

Страница 9: ...9 STEP 1 Fit left LEG B to frame underneath TOP A Assembly Instructions Install Left Leg Attach with SCREWS D using HEX KEY E...

Страница 10: ...10 Assembly Instructions Install Right Leg STEP 1 Fit right LEG B to frame underneath TOP A Attach with SCREWS D using HEX KEY E...

Страница 11: ...11 Assembly Instructions Connect Motors STEP 4 Plug in motors on LEGS B to controller box plugs on TOP A...

Страница 12: ...nal Steps Lift with 2 people STEP 5 Attach FEET C to LEGS B with SCREWS D and HEX KEY E Tip Take this time to make sure all screws have been tightened STEP 6 With another person lift and tilt the tabl...

Страница 13: ...wer outages or simply due to use Adjust Height Press and hold the UP ARROW to lift Press and hold the DOWN ARROW button to lower Save Height Press and hold the M button Number buttons for 1 to 3 secon...

Страница 14: ...lision protection activated Remove objects from beneath the desk and re initialize system Problem Action Desk does not go up or down and the con troller does not illuminate when any button is pressed...

Страница 15: ...consequential costs expenses or damages incurred by the customer or other user This warranty covers only the Seville Classics AIRLIFT Tempered Glass Electric Standing Desk with Dual USB Charger sold...

Страница 16: ...mum Height 29 Footprint 45 7 W x 23 75 D Lifting Speed 1 5 per second Base Weight 82 9 lbs Customer Service Information Telephone 800 323 5565 Fax 310 533 3899 Hours 8 30 AM 4 30 PM PST Email Support...

Отзывы: