Chapter 5:
Timing
67
v3.3-a 12/07/2022
5.2.1.8.1 Fanout ports configuration
The presets define the type of protocol selected for all the interfaces. If the user needs a specific
combination that mixes WR on some ports and PTP/IEEEE-1588 on others, he/she first select the
Custom preset and then configure the Fan-out ports.
5.2.1.8.1.1 Through Web
After applying the Custom profile under the Timing > General > Configuration tab, the user might
need to wait few seconds until the preset is completely loaded.
Then by clicking on the (+) icon of the Fanout Configuration panel, all the remaining interfaces
will be available for configuration. The user should then just change the protocol used by a
specific interface and its role (e.g, in Figure the wr4 port is used as PTP master).
Figure 5:6 - Mixing PTP and WR master ports (wr0 & wr1) on the WR-TP
5.2.1.8.1.2 Through CLI
As shown in §Figure , the user first needs to select the preset=Custom to reveal the Ports
Configuration submenu and other parameters.
Figure 5:7 - Custom Preset with CLI tool
Then each port can be configured independently with:
•
Protocol:
WR, PTP, Disabled
•
Role:
Master, Slave, Auto
1
, Survey
•
Source Rank:
[0-255], Order the timing source given the source rank priorities where:
o
1 is the first source to be executed and 255 the last one.
1
The Role Auto has been designed for BMCA but for the moment it is not fully supported
Содержание WR-Z16
Страница 2: ...Chapter 1 Introduction 2 v3 3 a 12 07 2022 ...
Страница 10: ...Chapter 1 Introduction 10 v3 3 a 12 07 2022 ...
Страница 72: ...Chapter 5 Timing 72 v3 3 a 12 07 2022 ...
Страница 148: ...Chapter 8 Device Maintenance 148 v3 3 a 12 07 2022 ...
Страница 159: ...Chapter 9 Troubleshooting 159 v3 3 a 12 07 2022 Severity info local0 rsyslog server1 IP local0 rsyslog server2 IP ...