Commissioning of the unit
Connect the toilet to the electrical supply. Open the water
supply completely in order to have an efficient rising
stage. To activate the flushing cycle, push the button
mounted on the rear edge of the pan. Throw a few toilet
paper sheets in the bowl and start the cycle again.
Attention: The basin tap should be watertight. Any drip-
ping will cause the motor to activate in regular short
bursts.
Use
ADMIRAL Compact can be used like a "normal" WC and
does not require any special maintenance.
Warning: as a normal WC, ADMIRAL Compact should
only be used for the evacuating of normal human waste,
toilet paper and household WC cleansers. Damage may
occur to the machine if the following are disposed of via
the WC; cotton wool, tampons, sanitary towels, wet wipes,
kitchen towels, condoms as well as other fabric or hard
objects. Solvents, acids and other chemicals can also
cause damage to the unit, and will invalidate the warranty.
Warning: In case of a long electrical shut off (vacation,
strike, work being done on the electrical or water supply)
close the water supply.
Cleaning
To clean the bowl use regular bathroom cleaning products.
To avoid accumultions of scale inside the motor, we advise
you to clean it regularly. To do so:
· Shut off water supply
· Flush the toilet
· Pour one liter of bathroom cleaning product
or (vinegar) in the bowl.
· Leave sit for a few hours
· Open water supply and flush the toilet
several times.
The frequency of cleaning depends on the hardness of the
water in your area. We advise you to do it at least once a
year. Do not put acids, caustic sodas or solvents down
ADMIRAL Compact.
For a long life of your unit...
· Regular cleaning
· Please use only normal toilet paper. Humidified paper might block the mace-
rating unit.
· The use of a filter between shut off valve and the toilet is not useless.
· In case of longer absence (holidays) close the water supply
· First vertical and the horizontal discharge. Otherwise (or diagonal) evacua-
tion may damage the motor unit.
Fault finding / Remedies
For the most part any inconsistencies in the operation of the unit will be minor
and easily rectified. Please refer to the chart below. If the problem cannot be
easily remedied in this way, please call our service organisation.
Warning: Always disconnect the electricity supply before attempting any work
on the unit !!!
Symptom
Possible Cause
The flushing cycle
activates normally, the
motor turns, but the
water leaves the pan
slowly or not at all
The motor activates
with a mechanical /
rattling sound
The cycle starts, but
water enters into the
pan too slowly or not
at all.
·The one way valve
(48) is not operating
normally
· The discharge pipe is
blocked
· The grille (62) is bloc-
ked
A foreign object has
entered the blade / grille
area (65/62)
· water inlet filter on
electrovalve (28) bloc-
ked.
· The electrovalve is
defective.
· Remove and clean the
filter
· Replace the electrovalve
Remedy
· Clean or replace valve
· Remove and clean
· Remove and clean
Remove the motor block,
take out the foreign object
through the opening in
motor cover (22). If
unsuccessful, dismantle.