SES-FA16UB Set Up Instructions
1. Secure the units in a safe loca on, where they will not be subject to im
‐
pact and where there is room around the unit so nothing will interfere
with the
fi
ber op c cabling causing it to bend sharply in a ght radius in
any way that can severely a
ff
ect the signal transfer.
2. Carefully connect your source(s) to the transmi er input(s) and the re
‐
ceiver unit output(s) to your receiving device input(s) using the RCA con
‐
nectors on the transmi er and on the receiver unit,
3. Please note that all audio on the transmi er (Tx) and receiver (Rx) must
be line level.
4. CLEAN* the ST
fi
ber op cal cable contacts that will be used for con
‐
nec ng the Tx and Rx units and a ach the
fi
ber cable to the
ST connec ons and secure, as you would secure a bayonet BNC. While
pressing lightly in on the connector, twist it in a clockwise direc on about
1/8 to 1/4 of a turn and then release. The connector should stay inserted
and have backwards spring pressure holding the bayonet in place.
5. Connect the included power supplies to the transmi er & receiver units,
and plug them both into an AC power source (100v
‐
240v AC 50/60Hz).
* CLEAN: All
fi
ber op cal cable contacts (the end that is inserted and makes
contact to enable lightwave transmission through the
fi
ber)
require cleaning each me before inser ng into a device’s outputs or inputs.
Failure to clean the contacts can damage the unit’s op cs over me and also
render the cable and the device permanently useless.
Use cleaning kits designed speci
fi
cally for
fi
ber op cs. Other cleaners may add
contaminants not seen by the naked eye which could damage cables and/or
equipment.