SES SE-3010 Скачать руководство пользователя страница 21

 

 
 

SEALED ENERGY SYSTEMS

®

 

21 

User Manual  

      

3.5. 

Passive Safety Protection     

 
3.5.1.  Overview of Operations 
 
The  battery  pack  is  fitted  with  additional  components  to  protect  it 
against  abusive  charge  and  discharge  conditions.  These  are  in 
addition to the electronic protection. 
 
3.5.2.  Thermal Fuse 
 
A Thermal Fuse is fitted in series with the charge/ discharge path to 
protect  the  battery  from  over  temperature.  This  device  goes  open 
circuit  if  the  cell  case  temperature  reaches  the  fuse's  temperature 
rating of 93°C (+0°C, -5°C). The fuse is non-re-settable rendering the 
battery pack non-functional. 
 
 

3.6. 

Mechanical Specifications      

 
3.6.1.    Weight  

 

 

0.490Kg, approximately 

 
3.6.2.    Mating Connector 
 

The recommended interconnection mating male connector is 

 

AMP/ TE part no.

 

TE-6123738-7 

 
3.6.3.    Packing  
 

The batteries are packaged in bulk per current regulations. 

3.7.   Environmental/Safety Specifications       

 
3.7.1.  EMC and Safety  
 
The battery complies with the following: 
• 

EMC Directive 2004/108/EC 

• 

Low Voltage Directive 2006/95/EC 

• 

Battery Recycling Directive 2006/66/EC as amended 

• 

RoHS Directive 2011/65/EU 

 
The  battery  has  been  tested  in  accordance  with  the  UN  Manual  of 
tests  and  Criteria  part  III  subsection  38.3  (ST/SG/AC.10/11/Rev.3)  - 
more commonly known as the UN T1-T8 Transportation tests and has 
been found to comply with the stated criteria. [USDOT-E7052] 
 
The battery has the following approvals and the pack will be labeled 
according: 
 

 

EN/ IEC 61000-6-3: 2010 

 

EN/ IEC 61000-6-1: 2016 

 

EN/ IEC 62281: 2016  

 

EN/IEC 62133-2:2017 

 

CE 

 

BIS/ IS16046-2:2018 

 

REACH 

 

RoHS 
 

Содержание SE-3010

Страница 1: ...ery Model SE 3010 SE30100NR29 14 4V 5 7AH 82 08Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This information...

Страница 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Страница 3: ...d a typical capacity of 2 9Ah giving a battery pack of 14 4V and 5 7Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is f...

Страница 4: ...contact has been made wash the affected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove...

Страница 5: ...with local state and federal laws and regulations Consult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken...

Страница 6: ...Transport Regulations Expended Lithium Ion Battery packs are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be...

Страница 7: ...w 80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notif...

Страница 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Страница 9: ...charge A key slot is also present on each pack for mechanical alignment adjacent to the positive terminal The SMBus Clock and data lines require separate pull ups to system logic voltage NOT the batte...

Страница 10: ...can be obtained from the four on pack LED s with push button activation Charge control is used to provide optimal and safe charging requests to an SMBus level II or level III charger The system has th...

Страница 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Страница 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Страница 13: ...te Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a command to the sl...

Страница 14: ...t Battery Slave 3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus...

Страница 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Страница 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Страница 17: ...0 Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 3010 Device Chemistry 0x22 Returns a...

Страница 18: ...threshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Dis...

Страница 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Страница 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Curren...

Страница 21: ...g Connector The recommended interconnection mating male connector is AMP TE part no TE 6123738 7 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety Speci...

Страница 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 16 8 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Страница 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Страница 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...

Отзывы: