SES SE-2057-2 Скачать руководство пользователя страница 10

 

 
 

SEALED ENERGY SYSTEMS

®

 

10 

User Manual  

      

 

safe operation throughout the life cycle of the battery. 

 

The  fuel  gauge  determines  the  State-Of-Charge  (SOC)  by 

 

integrating the input and output  current  and  using  impedance 

 

tracking to accurately track the available capacity of the attached 

 

battery. To achieve the desired fuel-gauge accuracy,   high-

 

performance analog peripherals are used to monitor   capacity 

 

change,  battery  impedance,  open-circuit  voltage  and 

 

temperature.  These  factors  are  continually  applied  to  account 

 

for  battery  non-linearity  and  environmental  conditions.  This 

 

approach  provides  the  user  a  meaningful  and  repeatable 

 

capacity  measure  with  minimal  risk  of  overstating  run  time. 

 

Visually, the SOC can be obtained from the four on-pack LED’s 

 

with push- button activation. 

 

Charge control is used to provide optimal and safe charging 

 

requests to an SMBus level II or level III charger. 

 

The  system  has  three  modes  of  operation;  normal,  sleep  and 

 

shutdown.  In  normal  mode,  measurements,  calculations, 

 

protection  decisions  and  data  updates  are  made  on  1  sec 

 

intervals.  Between  these  intervals,  the  electronics  enters  a 

 

reduced power mode. Sleep mode is entered when the  system 

 

senses no host or charger present. While in this mode, battery 

 

parameters continue to be monitored at  regular  intervals.  The 

 

system  will  continue  in  this  mode  until  it  senses  host  activity

 

(communications or current flow). Shutdown mode occurs when 

 

the  battery  voltage  falls  below  2.3V/parallel  cell  group.  In  this 

 

mode,  parasitic  current  is  reduced  to  a  minimum  by  shutting 

 

down  the  micro-  controller  and  all  associated  circuitry.  If  this 

 

should  happen,  the  battery  will  require  an  initial  low  current 

 

charge  to  bring  the  battery  voltage  back  up  before  normal 

 

operation will resume. 

 

The battery pack block diagram is shown below. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Содержание SE-2057-2

Страница 1: ...ery Model SE 2057 2 SE20572NR29 7 2V 11 4AH 82 08Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This informatio...

Страница 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Страница 3: ...3 6V and a typical capacity of 2 85Ah giving a battery pack of 7 2V and 11 4Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The batt...

Страница 4: ...contact has been made wash the affected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove...

Страница 5: ...with local state and federal laws and regulations Consult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken...

Страница 6: ...th Transport Regulations Expended Lithium Ion Battery packs are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should b...

Страница 7: ...w 80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notif...

Страница 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Страница 9: ...tive terminal The SMBus Clock and data lines require separate pull ups to system logic voltage NOT the battery voltage Typically a 15K pull up resistor is used but please refer to the SMBus Specificat...

Страница 10: ...to provide optimal and safe charging requests to an SMBus level II or level III charger The system has three modes of operation normal sleep and shutdown In normal mode measurements calculations prot...

Страница 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Страница 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Страница 13: ...op condition Write Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a c...

Страница 14: ...3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus slave using th...

Страница 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Страница 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Страница 17: ...Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2057 2 Device Chemistry 0x22 Returns a...

Страница 18: ...hreshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Disc...

Страница 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Страница 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Curren...

Страница 21: ...nector The recommended interconnection mating male connector is AMP TE part no 5787428 1 or 5787421 1 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety...

Страница 22: ...00 charge discharge cycles where the charge phase is CC CV C 3 8 4 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Страница 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Страница 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...

Отзывы: