3.2.2.  DC Specifications 
 

PARAMETER 

LIMITS 

REMARKS 

Active mode current 
consumption 

<650

µ

When a host is detected 
(charging, discharging or 
communications)  

Standby mode current 
consumption 

<140

µ

When no host activity is 
detected  

Shut-down mode 
current consumption  

<1

µ

Any cell voltage falls below 
2300mV 

 
 
3.2.3.  Measurement Accuracy  

 
3.2.3.1. Voltage 

 

The  voltage  measurements  have  a  resolution  of  1mV.  The 
absolute accuracy of the reading is ±0.7% over the operating 
range.  Note  that  measurements  are  made  at  the  cell  stack 
(not the pack connector). Therefore, internal resistance drops 
due to the shunt, safety components, and contact resistance 
are not taken into consideration. 
 
 
 

3.2.3.2. Temperature 

 

The internal pack temperature is measured by an NTC 
thermistor  attached  to  the  cell  stack.  Temperature 
readings  have  a  resolution  of  0.1°K.  The  absolute 
accuracy  is  ±3°K  over  an  operating  range  of  -20°C  to 
+80°C. 
 

 
3.2.3.3.  Current 

 

The  current  measurements  have  a  resolution  of  1mA. 
The absolute accuracy of the reading is ±0.7% or ±3mA 
whichever is greater over the operating range. A guard 
band has been imposed around zero current (-3mA to 
+3mA). 
 

 

3.2.4.  LED Indication 

 

 

The  battery  can  directly  display  the  capacity 
information.  The  battery  capacity  is  displayed  as  the 
relative SOC.  Each  LED  segment represents  25  percent 
of the full charge capacity. The LED pattern definition is 
given  in  the  table  below.  The  LED’s  illuminate  for  4 
seconds  following  switch  activation.  If  the  battery 
voltage is too low, there will be no LED indication. 
 
 

Содержание SE-2040-3

Страница 1: ...ery Model SE 2040 3 SE20403NR29 10 8V 8 55AH 32 34Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This informati...

Страница 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Страница 3: ...ical capacity of 2 85Ah giving a battery pack of 10 8V and 8 55Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is fully...

Страница 4: ...contact has been made wash the affected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove...

Страница 5: ...with local state and federal laws and regulations Consult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken...

Страница 6: ...Transport Regulations Expended Lithium Ion Battery packs are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be...

Страница 7: ...w 80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notif...

Страница 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Страница 9: ...sent on each pack for mechanical alignment adjacent to the positive terminal The SMBus Clock and data lines require separate pull ups to system logic voltage NOT the battery voltage Typically a 15K pu...

Страница 10: ...n pack LED s with push button activation Charge control is used to provide optimal and safe charging requests to an SMBus level II or level III charger The system has three modes of operation normal s...

Страница 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Страница 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Страница 13: ...p condition Write Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a co...

Страница 14: ...3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus slave using th...

Страница 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Страница 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Страница 17: ...Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2040 3 Device Chemistry 0x22 Returns a...

Страница 18: ...hreshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Disc...

Страница 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Страница 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Curren...

Страница 21: ...nector The recommended interconnection mating male connector is AMP TE part no 5787428 1 or 5787421 1 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety...

Страница 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 12 6 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Страница 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Страница 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...

Отзывы: