background image

 

 
 

SEALED ENERGY SYSTEMS

®

 

User Manual  

      

TABLE OF CONTENTS 

 

1. 

REVISION HISTORY 

 

 

 

 

3

 

 

2. 

INTRODUCTION 

 

 

 

 

3

 

 

2.1. 

SCOPE   

 

 

 

 

 

2.2. 

BATTERY PACK OVERVIEW 

 

 

 

2.3. 

GENERAL PRECAUTIONS 

 

 

 

 

2.3.1.  Handling 

 

 

 

 

 

2.3.2.  Charge & Discharge 

 

 

 

 

2.3.3.  Storage  

 

 

 

 

 

2.3.4.  Disposal 

 

 

 

 

 

2.3.5.  Comply with Waste Regulation   

5  

3. 

REQUIREMENTS 

 

 

 

 

6

 

 

3.1. 

GENERAL REQUIREMENTS 

 

 

 

3.1.1.  Nominal Voltage 

 

 

 

3.1.2.  Rated Capacity   

 

 

 

3.1.3.  Initial Impedance 

 

 

 

3.1.4.  Discharge 

 

 

 

 

3.1.5.  Charge   

 

 

 

 

3.1.6.  Storage  

 

 

 

 

3.1.7.  Terminal Specifications   

 

 

3.2. 

FUEL-GAUGE ELECTRONICS 

 

 

 

3.2.1.  Overview of Operation   

 

 

3.2.2.  DC Specifications 

 

 

11 

 

3.2.3.  Measurement Accuracy   

 

11 

 

3.3. 

SMBUS AND SBD PARAMETERS

 

 

12 

 

3.3.1.  Overview of Operations   

 

12 

 

3.3.2.  SMBus Logic Levels 

 

 

 

12 

 

3.3.3.  SMBus Data Protocols   

 

 

12 

 

3.3.4.  SMBus Host-to-Battery Message Protocol 

13 

 

3.3.5.  SMBus Battery-to-Charger Message Protocol 

14 

 

3.3.6.  SMBus Battery Critical Message Protocol  

15 

 

3.3.7.  Host to Battery Messages (Slave Mode)   

15 

 

3.3.8.  Battery to Charger Messages (Master Mode) 

17 

 

3.3.9.  Critical Messages (Master Mode)  

 

17 

 

3.3.10.  Pack Calibration Cycle   

 

 

19 

3.4. 

PROTECTION ELECTRONICS 

 

 

 

19 

 

3.4.1.  Overview of Operation   

 

 

19 

 

3.4.2.  Charge Protection 

 

 

 

19 

 

3.4.3.  Discharge Protection 

 

 

 

20 

 

3.4.4.  Short-Current Protection 

 

 

20 

3.5. 

PASSIVE SAFETY PROTECTION 

 

 

 

21 

 

3.5.1.  Overview of Operation   

 

 

21 

 

3.5.2.  Thermal Fuse   

 

 

 

21 

3.6. 

MECHANICAL SPECIFICATIONS

 

 

 

21 

 

3.6.1.  Weight   

 

 

 

 

21 

 

3.6.2.  Mating Connector 

 

 

 

21 

 

3.6.3.  Packaging 

 

 

 

 

21 

3.7. 

ENVIRONMENTAL/SAFETY SPECIFICATIONS

   

21 

 

3.7.1.  EMC and Safety  

 

 

 

21 

3.8. 

RELIABILITY

   

 

 

 

 

22 

 

3.8.1.  Life Expectancy   

 

 

 

22 

 

3.8.2.  Warranty 

 

 

 

 

22 

 

3.8.3.  Shelf Life 

 

 

 

 

23 

4.0. 

MECHANICAL DRAWING

 

 

 

 

24 

 

Содержание SE-2010

Страница 1: ...ery Model SE 2010 SE20100NR29 10 8V 5 7AH 61 56Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This information...

Страница 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Страница 3: ...al capacity of 2 85Ah giving a battery pack of 10 8V and 5 7Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is fully SMB...

Страница 4: ...contact has been made wash the affected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove...

Страница 5: ...with local state and federal laws and regulations Consult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken...

Страница 6: ...Transport Regulations Expended Lithium Ion Battery packs are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be...

Страница 7: ...80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notifi...

Страница 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Страница 9: ...k and data lines require separate pull ups to system logic voltage NOT the battery voltage Typically a 15K pull up resistor is used but please refer to the SMBus Specification for additional info 3 2...

Страница 10: ...charging requests to an SMBus level II or level III charger The system has three modes of operation normal sleep and shutdown In normal mode measurements calculations protection decisions and data up...

Страница 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Страница 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Страница 13: ...p condition Write Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a co...

Страница 14: ...Battery Slave 3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus...

Страница 15: ...he originator of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message S...

Страница 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Страница 17: ...0 Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2010 Device Chemistry 0x22 Returns a...

Страница 18: ...threshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Dis...

Страница 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Страница 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Curren...

Страница 21: ...ection mating male connector is AMP TE part no 5787428 1 or 5787421 1 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety Specifications 3 7 1 EMC and Saf...

Страница 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 12 6 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Страница 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Страница 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...

Отзывы: