INSTALLATION 

The  operations  described  in  the  paragraphs  of  this  chapter  provide  both  electrical  and  mechanical 
connections of the actuator, as well as the execution of test motions at reduced speed and motor torque or 
with small displacement steps. 

6.1

 

Safety warnings 

 

MOTORS  CANNOT  BE  CONNECTED  DIRECTLY  TO  THE  ELETRICITY  GRID.  A  PROPER  CIRCUITS  AND 
DEVICES FOR MOVEMENT MANAGEMENT ON BOTH DIRECTIONS IS REQUIRED. STROKE END LIMIT 
SWITCHES  (MICROSWITCHES  OR  SENSORS)  MUST  BE  CONTROLLED  TO  BE  SURE  THE  LINEAR 
MOVEMENT OF THE ACTUATOR (DUE TO THE OPERATION OF THE MOTOR OR TO THE INERTIA OF 
THE MOVING PARTS) STOPS BEFORE TO REACH THE MECHANICAL STROKE END LIMITS. IN CASE THIS 
HAPPENS, THE ACTUATOR CAN BE LOCKED AND THE INTERNAL COMPONENTS CAN BE DAMAGED. 

 

WHEN THE MOTORS MUST BE POWERED BY A CONVERTER (ELECTRIC DRIVE), THIS MUST BE CHOSEN 
BY QUALIFIED PERSONNEL. 

 

IN  CASE  THERE  ARE  INVOLVED  ELECTRONIC  DRIVE  AND  CONTROL  DEVICES  ON  THE  ACTUATOR 
MOVING  CONTROL,  REFER  TO  MANUALS  FOR  ALL  THE  NECESSARY  INFORMATION  AND  CORRECT 
INSTALLATION AND MAINTENANCE OF THE PRODUCT. 

 

BEFORE TO PROCEED TO THE ELECTRIC CONNECTION, MAKE SURE THE SUPPLY VOLTAGE IS TURNED 
OFF. 

 

BEFORE TO TURN-ON THE MOTOR, MAKE SURE THE ELECTRIC CONNECTIONS ARE TIGHTENED AND 
STABLE. 

 

CHECK  POWER  SUPPLY  CABLES  NOT  TO  BE  DAMAGED  DURING  THE  COMMISSIONING.  POWER 
SUPPLY CABLES MUST BE OUT OF HEAT SOURCES AND MOVING ORGANS. 

 

DURING FUNCTIONING ARE PRODUCED MAGNETIC, ELECTRIC AND ELECTROMAGNETIC FIELDS. THIS 
MAY  BE  DANGEROUS  FOR  PEOPLE  THAT  USE  CARDIAC  STIMULATOR  (PACEMAKER),  IF  NOT 
SUFFICIENT DISTANCE. 

 

DO NOT DISCONNECT ANY CONNECTION DURING OPERATION OR IN PRESENCE OF SUPPLY VOLTAGE. 

 

BEFORE TO TURN-ON THE MOTOR, MAKE SURE THE MECHANICAL CONNECTIONS OF THE ACTUATOR 
REMAIN TIGHTENED AND STABLE, ALSO DURING THE OPERATION. 

 

DURING THE COMMISSIONING, UNEXPECTED MOVEMENT OF THE MOTOR MAY BE CAUSED BY: 

 

WIRING ERRORS 

 

MOUNTING ERRORS 

 

DAMAGES ON POWER SUPPLY CABLES  

 

HARDWARE OR SOFTWARE ERRORS 

 

DRIVER PARAMETERS ERRORS 

 

OPERATION  IN  CONDITIONS  OUTSIDE  THE  SPECIFICATIONS  PROVIDED  BY  THE 
CATALOG AND THIS MANUAL 

 

MAKE  SURE  THE  SAFETY  PROTECTION  OF  THE  MACHINE  (MECHANICAL  AND  ELECTRICAL)  ARE 
ACTIVE.  

DURING  OPERATION,  TEMPERATURE  OF  THE  EXTERNAL  SURFACE  OF  MOTORS  CAN  REACH  HIGH 
TEMPERATURES. HOT SURFACES ON ACTUATOR CAN CAUSE BURNS AND SHOULD NOT BE TOUCHED 
 

 

Содержание UAL 1

Страница 1: ...UAL 3 UAL 4 UAL 5 UBA 1 UBA 2 UBA 3 UBA 4 UBA 5 Installation operation and maintenance manual Publication 04 01 02 03 04 05 E Rev 01 Data M Y 10 19 Servomech S p A Via M Calari 1 40011 Anzola dell Em...

Страница 2: ...relieve Servomech S p A from any liability for damage caused to persons and or property Servomech S p A it does not assume direct or indirect responsibility for an improper use of the actuator not re...

Страница 3: ...Thermal limit 8 4 2 Personnel requirements Qualifications 8 STORAGE 8 INSTALLATION 9 6 1 Safety warnings 9 6 2 FCM magnetic stroke limit switches 10 6 3 FCP inductive proximity stroke limit switches 1...

Страница 4: ...51 7345 74 Website www servomech com e mail info servomech com 2 2 Description of the product For all the technical characteristics of the product performance features dimensions refer to the technica...

Страница 5: ...of the input drive 3 Stroke length is the stroke length in millimetres achievable by the actuator 4 Linear speed is the linear speed expressed in mm s when the actuator is provided with electric moto...

Страница 6: ...and transporting the linear actuator the push rod must be in retracted position Lift the actuator from the housing and outer tube supporting the motor during transport DO NOT lift the actuator from th...

Страница 7: ...h a purely axial applied load They must be subjected to the loading and speed conditions specified in the catalog Modification of parts of the actuator or replacement of components with different and...

Страница 8: ...t ambient temperature 25 C without risk of internal parts overheating 10 10 100 Linear drive Fi Acme screw UAL series 30 Ball screw UBA series 100 For the proper operation of acme screw linear actuato...

Страница 9: ...NSTALLATION AND MAINTENANCE OF THE PRODUCT BEFORE TO PROCEED TO THE ELECTRIC CONNECTION MAKE SURE THE SUPPLY VOLTAGE IS TURNED OFF BEFORE TO TURN ON THE MOTOR MAKE SURE THE ELECTRIC CONNECTIONS ARE TI...

Страница 10: ...e refer to the product catalogue or to the check sheet supplied with the actuator When using more contact reeds for intermediate positions it shall be considered that the same reed switch can give the...

Страница 11: ...ED SWITCHES TECHNICAL FEATURES Contact NC NO Switching output Reed Supply voltage 5 120 V AC DC 1 5 230 V AC DC 2 Voltage drop 0 35 V Continous current 100 mA AC Switching capacity 6 W Protection clas...

Страница 12: ...switches are supplied already mounted on the actuator and set to the correct sensing distance DO NOT CHANGE THE SENSING DISTANCE OF PROXIMITY SWITCHES BY MOVING THE TWO NUTS FIXED ON THE SENSOR In ca...

Страница 13: ...i directional Resolution 100 or 500 pulses per revolution Output PUSH PULL 2 channels A and B phase difference 90 channel ZERO Input voltage 5 24 V DC No load current 100 mA Max commutable current 50...

Страница 14: ...arately powered f AC 3 phase motor with DC brake separately powered AC 2 phase with rectifier g AC 3 phase motor with DC brake separately powered In case of brake motor the brake is NORMALLY CLOSED NE...

Страница 15: ...diagrams to power supply of AC 3 ph motor Figure 6 4 Electric wiring diagrams to motor terminal board of AC 3 ph motor IN CASE OF ELECTRIC MOTOR DIFFERENT FROM THE ABOVE MENTIONED PLEASE REFER TO INST...

Страница 16: ...VE action When the power supply is switched off the brake is engaged The brake opens only when power is supplied the brake is wired separately make sure that the correct voltage is used if the brake i...

Страница 17: ...tched off the brake is engaged The brake opens only when power is supplied the brake is wired separately make sure that the correct voltage is used if the brake is equipped with hand release device ma...

Страница 18: ...INPUT SHAFT OR USE THE MOTOR BRAKE ALL MECHANICAL AND ELECTRICAL PROTECTION MUST BE INSTALLED AND ACTIVATED TO PREVENT DAMAGE TO PERSONS OR PROPERTY Check that all plant fixing elements are well mach...

Страница 19: ...G OF THE ACTUATOR AND PLANT CANNOT BE GUARANTED IF SIDE OR NOT AXIAL LOAD ARE APPLIED TO THE ACTUATOR 6 7 Installation of rod end fitting elements To install a mounting element on the rod end threaded...

Страница 20: ...ed Measure the initial length of the actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the current actu...

Страница 21: ...SHELL Gadus S2 V100 2 Grease NLGI 1 DIN 51818 LUBCON Thermoplex ALN 1001 Also suitable FUCHS Renolit AX 2P NLGI 2 AGIP Grease AC 1 NLGI 1 MOBIL Mobilgrease FM 101 NLGI 1 KLUBER Klubersynth UH1 14 151...

Страница 22: ...ide require periodic relubrication according to Table 9 1 or at the latest after 1 year of time Please use lubricant indicated in Table 8 1 or equivalent Every 2 months time interval visual inspection...

Страница 23: ...tween one lubricating operation and the next When lubricating the linear drive the actuator must always be in EXTENDED La POSITION Do not lubricate the linear screw drive in retracted Lc or intermedia...

Страница 24: ...REQUIRED ONLY FOR UAL UBA 5 ACTUATORS Relube the push rod guide using proper grease nipples as shown on Fig 9 3 Grease nipple type DIN71412 M6 Figure 9 3 Lubrication of push rod guide for UAL UBA 5 Ap...

Отзывы: