Servomech UAL 1 Скачать руководство пользователя страница 1

Servomech S.p.A. 

04.01-02-03-04-05.E - Rev. 01 DD (M/Y) 10/19 

 

LINEAR ACTUATORS 

UAL 1 – UAL 2 – UAL 3 – UAL 4 – UAL 5 

UBA 1 – UBA 2 – UBA 3 – UBA 4 – UBA 5 

Installation, operation and maintenance manual 

 

 

Publication: 04.01-02-03-04-05.E - Rev. 01 Data (M/Y) 10/19 

 

Servomech S.p.A. 

Via M. Calari, 1 - 40011 Anzola dell’Emilia (BO) - ITALY 

Ph: + 39 051 6501711  Fax: + 39 051 734574   

www.servomech.com 

info@servomech.

co

Содержание UAL 1

Страница 1: ...UAL 3 UAL 4 UAL 5 UBA 1 UBA 2 UBA 3 UBA 4 UBA 5 Installation operation and maintenance manual Publication 04 01 02 03 04 05 E Rev 01 Data M Y 10 19 Servomech S p A Via M Calari 1 40011 Anzola dell Em...

Страница 2: ...relieve Servomech S p A from any liability for damage caused to persons and or property Servomech S p A it does not assume direct or indirect responsibility for an improper use of the actuator not re...

Страница 3: ...Thermal limit 8 4 2 Personnel requirements Qualifications 8 STORAGE 8 INSTALLATION 9 6 1 Safety warnings 9 6 2 FCM magnetic stroke limit switches 10 6 3 FCP inductive proximity stroke limit switches 1...

Страница 4: ...51 7345 74 Website www servomech com e mail info servomech com 2 2 Description of the product For all the technical characteristics of the product performance features dimensions refer to the technica...

Страница 5: ...of the input drive 3 Stroke length is the stroke length in millimetres achievable by the actuator 4 Linear speed is the linear speed expressed in mm s when the actuator is provided with electric moto...

Страница 6: ...and transporting the linear actuator the push rod must be in retracted position Lift the actuator from the housing and outer tube supporting the motor during transport DO NOT lift the actuator from th...

Страница 7: ...h a purely axial applied load They must be subjected to the loading and speed conditions specified in the catalog Modification of parts of the actuator or replacement of components with different and...

Страница 8: ...t ambient temperature 25 C without risk of internal parts overheating 10 10 100 Linear drive Fi Acme screw UAL series 30 Ball screw UBA series 100 For the proper operation of acme screw linear actuato...

Страница 9: ...NSTALLATION AND MAINTENANCE OF THE PRODUCT BEFORE TO PROCEED TO THE ELECTRIC CONNECTION MAKE SURE THE SUPPLY VOLTAGE IS TURNED OFF BEFORE TO TURN ON THE MOTOR MAKE SURE THE ELECTRIC CONNECTIONS ARE TI...

Страница 10: ...e refer to the product catalogue or to the check sheet supplied with the actuator When using more contact reeds for intermediate positions it shall be considered that the same reed switch can give the...

Страница 11: ...ED SWITCHES TECHNICAL FEATURES Contact NC NO Switching output Reed Supply voltage 5 120 V AC DC 1 5 230 V AC DC 2 Voltage drop 0 35 V Continous current 100 mA AC Switching capacity 6 W Protection clas...

Страница 12: ...switches are supplied already mounted on the actuator and set to the correct sensing distance DO NOT CHANGE THE SENSING DISTANCE OF PROXIMITY SWITCHES BY MOVING THE TWO NUTS FIXED ON THE SENSOR In ca...

Страница 13: ...i directional Resolution 100 or 500 pulses per revolution Output PUSH PULL 2 channels A and B phase difference 90 channel ZERO Input voltage 5 24 V DC No load current 100 mA Max commutable current 50...

Страница 14: ...arately powered f AC 3 phase motor with DC brake separately powered AC 2 phase with rectifier g AC 3 phase motor with DC brake separately powered In case of brake motor the brake is NORMALLY CLOSED NE...

Страница 15: ...diagrams to power supply of AC 3 ph motor Figure 6 4 Electric wiring diagrams to motor terminal board of AC 3 ph motor IN CASE OF ELECTRIC MOTOR DIFFERENT FROM THE ABOVE MENTIONED PLEASE REFER TO INST...

Страница 16: ...VE action When the power supply is switched off the brake is engaged The brake opens only when power is supplied the brake is wired separately make sure that the correct voltage is used if the brake i...

Страница 17: ...tched off the brake is engaged The brake opens only when power is supplied the brake is wired separately make sure that the correct voltage is used if the brake is equipped with hand release device ma...

Страница 18: ...INPUT SHAFT OR USE THE MOTOR BRAKE ALL MECHANICAL AND ELECTRICAL PROTECTION MUST BE INSTALLED AND ACTIVATED TO PREVENT DAMAGE TO PERSONS OR PROPERTY Check that all plant fixing elements are well mach...

Страница 19: ...G OF THE ACTUATOR AND PLANT CANNOT BE GUARANTED IF SIDE OR NOT AXIAL LOAD ARE APPLIED TO THE ACTUATOR 6 7 Installation of rod end fitting elements To install a mounting element on the rod end threaded...

Страница 20: ...ed Measure the initial length of the actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the current actu...

Страница 21: ...SHELL Gadus S2 V100 2 Grease NLGI 1 DIN 51818 LUBCON Thermoplex ALN 1001 Also suitable FUCHS Renolit AX 2P NLGI 2 AGIP Grease AC 1 NLGI 1 MOBIL Mobilgrease FM 101 NLGI 1 KLUBER Klubersynth UH1 14 151...

Страница 22: ...ide require periodic relubrication according to Table 9 1 or at the latest after 1 year of time Please use lubricant indicated in Table 8 1 or equivalent Every 2 months time interval visual inspection...

Страница 23: ...tween one lubricating operation and the next When lubricating the linear drive the actuator must always be in EXTENDED La POSITION Do not lubricate the linear screw drive in retracted Lc or intermedia...

Страница 24: ...REQUIRED ONLY FOR UAL UBA 5 ACTUATORS Relube the push rod guide using proper grease nipples as shown on Fig 9 3 Grease nipple type DIN71412 M6 Figure 9 3 Lubrication of push rod guide for UAL UBA 5 Ap...