Servomech ATL 50 Скачать руководство пользователя страница 1

Servomech S.p.A. 

02.50-63-80.E - Rev. 03 Date (M/Y) 12/19 

 

LINEAR ACTUATORS 

ATL 50 – ATL 63 – ATL 80 

BSA 50 – BSA 63 – BSA 80 

Installation, operation and maintenance manual 

 

 

Publication: 02.50-63-80.E - Rev. 03 Date (M/Y) 12/19 

 

Servomech S.p.A. Via M. Calari, 1 - 40011 Anzola dell’Emilia (BO) - ITALY 

Ph: + 39 051 6501711  Fax: + 39 051 734574   

www.servomech.com  [email protected] 

Содержание ATL 50

Страница 1: ...TL 50 ATL 63 ATL 80 BSA 50 BSA 63 BSA 80 Installation operation and maintenance manual Publication 02 50 63 80 E Rev 03 Date M Y 12 19 Servomech S p A Via M Calari 1 40011 Anzola dell Emilia BO ITALY...

Страница 2: ...elieve Servomech S p A from any liability for damage caused to persons and or property Servomech S p A it does not assume direct or indirect responsibility for an improper use of the actuator not resp...

Страница 3: ...strictions 7 4 1 2 Standard operating conditions 8 4 1 3 Thermal limit 8 4 2 Personnel requirements Qualifications 8 5 STORAGE 8 6 INSTALLATION 9 6 1 Safety warnings 9 6 2 FCE electric stroke limit sw...

Страница 4: ...www servomech com e mail info servomech com 2 2 Description of the product For all the technical characteristics of the product performance features dimensions refer to the technical catalog Main act...

Страница 5: ...f the input drive 3 Stroke length is the stroke length in millimetres achievable by the actuator 4 Linear speed is the linear speed expressed in mm s when the actuator is provided with electric motor...

Страница 6: ...r before transporting the product Lift the actuator from the housing and outer tube using suitable slings DO NOT lift the actuator from the push rod and or the motor Prevent the actuator from swinging...

Страница 7: ...a purely axial applied load They must be subjected to the loading and speed conditions specified in the catalog Modification of parts of the actuator or replacement of components with different and n...

Страница 8: ...ambient temperature 25 C without risk of internal parts overheating 10 10 100 Linear drive Fi Acme screw ATL series 30 Ball screw BSA series 100 For the proper operation of acme screw linear actuators...

Страница 9: ...STALLATION AND MAINTENANCE OF THE PRODUCT BEFORE TO PROCEED TO THE ELECTRIC CONNECTION MAKE SURE THE SUPPLY VOLTAGE IS TURNED OFF BEFORE TO TURN ON THE MOTOR MAKE SURE THE ELECTRIC CONNECTIONS ARE TIG...

Страница 10: ...ixes the required RETRACTED ACTUATOR stop position Ring 2 activates FC 2 switch and fixes the required EXTENDED ACTUATOR stop position To setup the stop positions simply release the grub screw on the...

Страница 11: ...y switches are supplied already mounted on the actuator and set to the correct sensing distance DO NOT CHANGE THE SENSING DISTANCE OF PROXIMITY SWITCHES BY MOVING THE TWO NUTS FIXED ON THE SENSOR In c...

Страница 12: ...nput polarity inversion against any incorrect output connection Cable length 1 3 m Enclosure rating IP 55 The rotary encoder ENC 4 must be connected to the electric control circuit as shown in the fol...

Страница 13: ...ly powered f AC 3 phase motor with DC brake separately powered AC 2 phase with rectifier g AC 3 phase motor with DC brake separately powered In case of brake motor the brake is NORMALLY CLOSED NEGATIV...

Страница 14: ...agrams to power supply of AC 3 ph motor Figure 6 4 Electric wiring diagrams to motor terminal board of AC 3 ph motor IN CASE OF ELECTRIC MOTOR DIFFERENT FROM THE ABOVE MENTIONED PLEASE REFER TO INSTAL...

Страница 15: ...g elements are well machined and cleaned and that they fit the dimensions of the actuators fixing elements they have to be fixed to If the length of the actuator have to be changed push rod more retra...

Страница 16: ...O THE ACTUATOR 6 8 Installation of rod end fitting elements To install a fitting element on the rod end threaded bore BA use a wrench on the rod end for ATL BSA 50 or fix the push rod with a clamp for...

Страница 17: ...Measure the initial length of the actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the current actuat...

Страница 18: ...3 ATL 80 BSA 50 Grease NLGI 00 DIN 51818 AGIP Grease SLL 00 Grease NLGI 1 DIN 51818 LUBCON Thermoplex ALN 1001 Also suitable FUCHS Renolit DURAPLEX EP 2 NLGI 2 AGIP Grease AC 1 NLGI 1 MOBIL Mobilgreas...

Страница 19: ...nt leakage contact SERVOMECH Note for ATL BSA 50 the rear hinge material is auto lubricated and it does not require additional lubrication ACTUATOR Lead pitch Lubrication interval Linear drive lubr q...

Страница 20: ...ubricating operation and the next WHEN LUBRICATING THE LINEAR DRIVE THE ACTUATOR MUST ALWAYS BE IN EXTENDED La POSITION DO NOT LUBRICATE THE LINEAR SCREW DRIVE IN RETRACTED Lc OR INTERMEDIATE POSITION...

Страница 21: ...s with quantity indicated in Tab 9 1 Extend and retract the push rod over its entire stroke for 3 full cycles If necessary remove excess of lubricant from push rod 9 3 Rear hinge lubrication WARNING T...

Отзывы: