ServiceMASTER Clean 56380560 Скачать руководство пользователя страница 17

FORM NO. 56041955 - SOLUS 500 CSA - 

17

SOLUS-500-CSA

 Item  Ref. No. Qty  Description

  53 

FP592 

1  Pump complete, no mtr 

 

[ ] 

 

1    Pump, Piston Style, 300-500 Psi

 

[ ] 

 

1    Bearing & Cam Assembly

 

[ ] 

 

2    Quick Connect, Plug, Brass

 

[ ] 

 

1    Nipple, 1/4 Pipe, Brass

 

[ ] 

 

1    Hose Barb 1/4 Pipe X 1/2 Hose

 

[ ] 

 

1    Hose Barb, 90, Brass, 3/8”

 

[ ] 

 

1    Elbow, 90 Degree 3/8” Brass

 

[ ] 

 

1    Reducer, 3/8 Pipe Female

 

[ ] 

 

2    Bushing 3/8 X 1/4 Pipe, Brass

 

[ ] 

 

1    Elbow, 90 Deg 1/4” Mpt X 1/4”

 

[ ] 

 

1    Plug, Brass Pipe, 1/4 Pipe

 

[ ] 

 

1    Unloader Valve For 500 PSI

  54 

FP542 

1  Hose assembly, pump to gauge

 

[ ] 

 

1    Hose Pulsation Dampening 28”

 

[ ] 

 

1    Quick Connect, Brass, 1/4 FPT

 

[ ] 

 

1    Nipple, 1/4 Pipe, Brass

  55 

801D 

2  Hinge pin 4.75”

 56  27A  2 Axle 

Cap

 57  2092  2 Wheel, 

12”

 58 910-2375 1 Axle 

rod 

 60

#

   1 

Base 

NOTE 1

  61  CUPE-BLK  1  Castor Plate, Black
 62  905  2 Castor, 

4”

  63 

FP541 

1  Gauge, Pump pressure, with QD

 

[ ] 

 

1    Gauge, 2-1/2” 1000 PSI

 

[ ] 

 

1    Quick Connect, Brass, 1/4 FPT

 

[ ] 

 

1    Elbow, 1/4 Street, 90 Deg

  64 

928 

1  Louver, 3”, gray

 65  FP585  1 Castor 

Plate

 

[ ] 

 

1    Castor Plate Molded W/Handle Blk

 

[ ] 

 

1    Instruction sheet

 66

#

 56471194  1 Latch 

Assembly

  67 

45 

1  Quick Disconnect, male. 1/4 p.t.

 68  115 

3 Washer, 

fi

 ber

 69  116A  1 Bushing, 

Te

fl

 on

  70 

92A 

2  Nipple, 1/4 p.t. S/S

 71  216  1 Elbow 

Brass

  72 

FP540 

1  Heat Exchanger, complete

  73 

455 

1  Mount bracket, heater

  74 

223 

1  Quick Disconnect, male

 75  945D  1 Unloader 

valve

  77 

FP547 

1  Hose assembly, heater inlet

 

[ ] 

 

1    Hose Assy, Swivel 48F to 4-6

 

[ ] 

 

1    Elbow 90 Deg 1/8 x 1/8 P. Brass

  78 

2110 

1  Circuit Breaker, 15A

  79 

2111 

1  Terminal Block, for ground

  80 

1359 

1  Decal-USP Logo Round

  81 

2102A 

1  Decal-Solus 500 Right Side

  82 

2102 

1  Decal-Solus 500 Left Side

  83 

1503A 

1  Label, Danger Electric Shock

  84  56380692  1  Label, Danger Electric Shock
 

[ ] 

1531 

2  Screw 8-32 X 3/4 Pan Head Ph

 

[ ] 

2119 

2  Plug Quick-Wire Straight-Blad

 

[ ] 

1238 

1  Nut. Finish 2-56 Thread Zp

 

[ ] 

1233 

1  Screw 2-56 X1 Panhead Philip

 

[ ] 

306 

1  Nut Nylock 2-56 S/S

 

[ ] 

1532 

2  Screw 8-32 X 1/2 Pan Head P

 

[ ] 

316 

1  Nut Nylon Locking 4-40 Zinc

 

[ ] 

315A 

1  Screw 4-40 X 3/4 Panhead Phill

revised 5/11

 MISCELLANEOUS 

PARTS

 Item  Ref. No. Qty  Description

 

**  FP194E 

1  Heat repair kit includes thermistor 

 

 

 

    control, thermistor probe & cutout

 

** 

950CP 

1  Pump rebuild kit, valves & o-rings

 

** 

250 

1  Pump rebuild kit, piston & seals

 

** 

FP538 

1  Pump & motor complete w/unloader

 

[ ] 

 

1    Plug Brass Pipe 1/4 Pipe H

 

[ ] 

 

1    Elbow 90 Deg 1/4 Mpt X 1/4

 

[ ] 

 

1    Elbow 90 Degree 3/8 Brass

 

[ ] 

 

2    Bushing 3/8 X 1/4 Pipe Brass

 

[ ] 

 

2    Reducer 3/8 Pipe Female To 1

 

[ ] 

 

1    Tee Brass 1/4 Pipe

 

[ ] 

 

4    Capscrew 1/4-20 X 2 X 1

 

[ ] 

 

2    Quick Connect Plug Brass 1/

 

[ ] 

 

1    Hose Barb 90 Brass 3/8 Ba

 

[ ] 

 

1    Hose Barb 1/4 Pipe X 1/2 Hose.

 

[ ] 

 

1    Nipple Pipe Stainless Steel 1/

 

[ ] 

 

1    Unloader Valve For 500 Psi Pum

 

[ ] 

 

1    Motor Dc Volt100v 300/500 P

 

[ ] 

 

1    Bearing & Cam Assembly Size.0

 

[ ] 

 

1    Pump Piston Style 300-500 Ps

 

[ ] 

 

1    Thermostat Probe 120v. Tempert

      

#

 = Revised or new since last update

      [ ] = Not Shown
      ** = Optional, Not Included

#

 

NOTE 1:

 Order part number 56381643 “Solus-500 Base Drill Complete”.

 Item  Ref. No. Qty  Description

 

FP578 

2  Switch, DPDT, with cover

 

[ ] 

 

1    Switch Rocker DPST W/Light 120

 

[ ] 

 

1    Sheet, Instruction, Switch

 3  78B  1 

Light, 

red

 3A  78 

1 Light, 

green

 5  248  1 

Knob, 

red

  5A 

FP544 

1  Potentiometer, heat, w/wires & knob

 

[ ] 

 

1    Potentiometer, 10K for Heat

 

[ ] 

 

1    Knob, with Red Top for 1/4

 

[ ] 

 

39in    Wire, Yellow, 18 Gauge 500

 

[ ] 

 

37in    Wire, Red 18 Gauge

 6  249  1 

Knob, 

blue

  6A 

FP543 

1  Potentiometer, pump, w/wires & knob

 7 2093A  1 

Switch 

plate

 8 4404D  1 

Mating 

bar

 9 2106  2 

Handle

 9A  1590  2 Grip, 

handle

 10  2105  2 Wheel, 

handle

 

11 

2026A 

1  Float, electric, water level

  12 

801E 

2  Hinge pin 7”

 13  VUPE  1 Tank, 

Vacuum

  13A  VC-BLK1 

1  Cover, for vacuum motors

 14  2013A  2 Gasket, 

vacuum

 14A  2112 

2 Gasket, 

over

fl

 ow protection

  15 

408E 

2  Vacuum motor, 120V

  15A 

1589 

2  Screen, 1/8 S/S mesh

  16 

2086A 

1  Lid & ring, vacuum

 

[ ] 

 

1    O-Ring for 2086A Lid

 

[ ] 

 

1    Lid

 

[ ] 

 

1    Mounting Plate

  17 

1074 

1  Gasket, vacuum lid

 18  805  1 Chain, 

8”

  19 

907 

1  Hose barb, 1-1/2”

  20 

1130 

2  Strap, Velcro, 9”

 21

#

 56113071  1 Plug-Hose

 22  1518  1 Hose 

Clamp

 23  1060B  1 Hose, 

drain

 24  HUPE  1 Tank, 

Holding

  25 

FP545 

1  Lid and chain, Holding Tank

 

[ ] 

 

1    Lid Rotomolded White

 

[ ] 

 

1    Chain 8” w/ D Couplings

 26  909A  1 Latch 

strike

  28 

1113 

1  Hose barb, 90°, 1/2” hose

  29 

925 

1  Hose, 3/8” ID X 17”

 31  166  4 Hose 

clamp

  33 

946 

1  Hose, 1/2” ID X 20”

  34 

207A 

1  Filter, pump inlet

  36 

 See Miscellaneous **

  37 

918 

1  Heat Sink plate

  38 

FP361 

1  Motor Speed Control PCB, pump

 

[ ] 

 

1    Motor Speed Control

 

[ ] 

 

1    Resistor-Horsepower .05 Ohm

 

[ ] 

 

1    Instruction Sheet

  40 

FP225 

1  Vacuum Motor Control PCB

 41  2014  1 Fan, 

120V

 42  2015  1 Guard, 

fan

  43 

2B1 

4  Screw, 6-32 X 2-1/4”

  44 

1057B 

2  Power Cord, 12/3, 25 ft

  45 

1062 

2  Receptacle, AC power in

 46  1476  1 Strap, 

17”

  49 

FP336 

1  PCB mounting track, 4”

  50 

923B 

1  Dual Cord Sensor PCB

 51  198  1 Hose 

clamp

  52 

948B 

1  Motor, DC, for pump

Содержание 56380560

Страница 1: ...e 2 Keep machine from rain and snow extremes in temperatures and store in a heated location DO NOT let the machine or the wand freeze Do not use outdoors 3 Do not let the pump run dry 4 Use approved chemicals only NO SOLVENTS 5 Wear gloves or use rags when removing quick disconnects to prevent burns 6 Never use water above 130º F 54º C in the solution tank 6 07 revised 5 11 Form No 56041955 INFORM...

Страница 2: ... outdoors or dropped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated surfaces To unplug grasp the plug not the cord Do not handle the plug the cord or the machine with wet hands Extension cords must be 12 3 and no long...

Страница 3: ...uire any scheduled maintenance however the motors may require replacement brushes after 1000 1500 hours and the pump and bypass valve may require rebuild kits after 1000 1500 hours typically refer to machine part list for numbers Clean the body with an all purpose detergent and protect it with an automobile interior polish Lubricate the wheels castors and quick disconnects with an all purpose sili...

Страница 4: ...les are used to move the machine These handles allow you to tilt the machine back onto its 12 wheels for easy maneuvering and or for moving on stairways SWITCH PLATE The switches are located on the rear of the machine out of the way of water FAN Removes warm air from the component compartment PSI GAUGE indicates the pump pressure Look at the pressure while you spray LATCH The latch holds together ...

Страница 5: ... will be observable at the pressure gauge VACUUM SWITCH 4 This switch will illuminate when the vacuum motors are on The vacuum motors run off of cord 1 CIRCUIT LOCATOR 5 When this light is on it indicates that cord 2 Identified by the red H on the back of the extractor is on a separate line from cord 1 Cord 2 supplies voltage to the heater allowing it to heat to the temperature range indicated by ...

Страница 6: ...nks as necessary 9 When finished with the job vacuum all unused solution into the recovery tank and dump the tank Clean the tanks and filters Clean the tool and hoses Store the machine in a heated location ELECTRIC CIRCUIT LOCATOR This unique patented smart system operated by a solid state circuit will inform the operator when the two cords are plugged into separate lines by illuminating the green...

Страница 7: ...ree strokes Heat exchanger needs to be flushed Wrong tool being used Too much water passing through Longer hose or larger diameter hose than standard NO HEAT Heat is not turned on Either the green light must be on or the bypass switch must be turned on No power in the wall outlet check to see if the breaker has tripped No power to the bypass switch check wiring for opens No power out of bypass swi...

Страница 8: ... dans un endroit chauffé NE PAS laisser geler la machine ou le tube rallonge Ne pas l utiliser à l extérieur 3 Ne pas laisser la pompe fonctionner à sec 4 Utiliser uniquement les produits chimiques autorisés AUCUN SOLVANT 5 Porter des gants ou utiliser des chiffons lorsque vous retirez les raccords à démontage rapide pour éviter les brûlures 6 Ne jamais utiliser d eau à une température supérieure ...

Страница 9: ...centre de service Ne pas tirer sur le cordon utiliser le cordon comme une poignée fermer un porte sur le cordon ou enrouler le cordon autour de bords ou de coins acérés Ne pas faire passer la machine sur le cordon Éloigner le cordon des surfaces chauffées Pour débrancher tenir la fiche et non le cordon Ne pas manipuler la fiche le cordon ou la machine avec des mains mouillées Les cordons prolongat...

Страница 10: ...Products Le moteur d aspiration les moteurs de pompe et les pompes n ont pas besoin d un entretien de routine cependant les brosses des moteurs devraient être remplacer après 1000 ou 1500 heures et la pompe et la soupape de dérivation pourraient avoir besoin de kits de réusinage après 1000 ou 1500 heures consulter la lite des pièces pour les numéros Nettoyer la carrosserie avec un détergent tout u...

Страница 11: ...ermettent d incliner la machine vers l arrière sur ses roues de 12 po 30 cm pour une manoeuvre facile ou un déplacement dans les escaliers PLAQUE DE COMMUTATEUR Les commutateurs sont situés à l arrière de la machine à l écart de l eau VENTILATEUR Aspire l air chaud du compartiment des composants MANOMÈTRE indique la pression de la pompe Vérifier la pression quand vous vaporisez LOQUET le loquet re...

Страница 12: ...pe pourra être observé sur le manomètre INTERRUPTEUR D ASPIRATION 4 Cet interrupteur s allume quand les moteurs d aspiration fonctionnent Les moteurs d aspiration sont branchés sur le cordon No 1 LOCALISATEUR DE CIRCUIT 5 Quand le témoin lumineux est allumé le cordon No 2 Identifié par un H rouge à l arrière de l extracteur est sur un circuit séparé du cordon No 1 Le cordon No 2 alimente l élément...

Страница 13: ...ettoyer 8 Remplir et vider les réservoirs au besoin 9 Quand le travail est fini aspirer toute la solution inutilisée dans le réservoir de récupération et vidanger celui ci Nettoyer les réservoirs et les filtres Nettoyer l outil et les tuyaux flexibles Ranger la machine dans un endroit chauffé LOCALISATEUR DE CIRCUIT ÉLECTRIQUE Ce système intelligent unique breveté activé par un circuit à semi cond...

Страница 14: ...r durant 12 à 15 secondes à la fois ou environ trois coups Il faut vidanger l échangeur de chaleur Mauvais outil utilisé Trop d eau passe Tuyau flexible plus long ou d un diamètre plus large que standard PAS DE CHALEUR La chaleur ne fonctionne pas Le témoin lumineux vert doit être allumé ou le commutateur de dérivation doit être ouvert Pas de courant à la prise murale Vérifier si le disjoncteur ne...

Страница 15: ...NOTES SOLUS 500 CSA 56380560 120 V ...

Страница 16: ...26 28 31 45 36 37 40 38 51 46 55 57 56 58 62 60 64 66 67 68 53 52 73 70 72 51 50 49 1 5 3 3A 7 6 5A 6A 29 28 31 24 12 16 18 15 14 19 20 22 19 13 17 11 10 75 74 71 77 PUMP 9 26 34 63 54 54A 44 42 41 43 65 15A 9A 13A 23 Pump inlet hose Pump bypass hose 69 78 79 14A 81 82 80 83 84 ...

Страница 17: ...oader 1 Plug Brass Pipe 1 4 Pipe H 1 Elbow 90 Deg 1 4 Mpt X 1 4 1 Elbow 90 Degree 3 8 Brass 2 Bushing 3 8 X 1 4 Pipe Brass 2 Reducer 3 8 Pipe Female To 1 1 Tee Brass 1 4 Pipe 4 Capscrew 1 4 20 X 2 X 1 2 Quick Connect Plug Brass 1 1 Hose Barb 90 Brass 3 8 Ba 1 Hose Barb 1 4 Pipe X 1 2 Hose 1 Nipple Pipe Stainless Steel 1 1 Unloader Valve For 500 Psi Pum 1 Motor Dc Volt100v 300 500 P 1 Bearing Cam A...

Страница 18: ......

Страница 19: ......

Страница 20: ...425 322 0133 800 257 7982 FAX 425 322 0136 11015 47th Ave W Mukilteo WA 98275 VISIT US AT http www usproducts com ...