Servend FRP-250 Скачать руководство пользователя страница 2

Instructions

Manitowoc Beverage Systems Sellersburg, 

2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com

Subject: 

 FRP-250 Brixing

If the merchandiser and splash panel are on the front of the unit, remove them. Merchandiser removal will give you access to the syrup and 
water valves. Splash panel removal will give you access to the plumbing label located on the foam front and/or in the Plumbing section of the 
Use & Care Manual. This label will be needed to identify valve and corresponding key pad locations. 

1

 BRIX 

MODE

Mode 2 puts your Flav'R-Pic into brix mode, follow the steps below to put a 
board into brix mode. 

Choose a control board, if brixing drinks for N1 (

Nozzle 1

) or 

N3 use the left control board, if brixing drinks for N4 or N6 use 
the right control board. Beverage dispense points are 
designated by a black nozzle.

Press the program button and hold for 3 seconds or until the 

LED displays 1. Press the program button again until 2 is 
displayed on the control board LED display.

CHECK BRIX

NOTE: 
Use of a funnel is recommended to direct the syrup or water 
into the correct chamber of the cup.

Place the funnel and standard brix cup under the dispense point of 

the water or syrup being tested and press its key pad button. The 
water or syrup will be dispensed for a fixed duration in order to 
check your ratios.

Remove the brix cup from the dispenser and tap on the 

counter 3 times to remove bubbles. Then place on a level 
surface. The correct carbonated or non-carbonated water volume 
should be even with the syrup volume level + / - 2 bandwidths.

3

 ADJUST 

BRIX

Clockwise movement of the valve brix nut adjustment screw 

increases the flow rate and counter clockwise restricts the 
syrup or water flow. Use the illustration on the right for valve 
location reference.

When finished, move on to another nozzle or if brixing is 

complete, return the control board to the dispense mode by 
pressing the program button and holding for 3 seconds or until 
the LED displays 0. 

Replace the splash panel and merchandiser.

SYRUP

WATER

FUNNEL

Standard Brix Cup

0

2

Brixing

Info

Left Side

Program

Button

Right Side 
Program 
Button

10/13

S5

S4

F2

F1

S9

S8

F3

F4

C1     S1

S2     S3

S6     S7

C2     NC2

C3     NC3

S11    S10

S15     S14

Valve

Valve

Valve

Valve

Valve

Valve

Valve

Valve

Valve

Valve

Valve

Valve

Valve

Valve

C4     S16

F6

F5

F7

F8

S13

S12

S1

S3

S2

S4

S5

S7

S6

S8

F1

F2 F4

F3

N1

N3

S12

S10

S11

S9

S16

S14

S15

S13

F5

F6 F8

F7

N4

N6

S1, S2, S3, S4, F1

S5, S6, S7, S8, F2, F3

S9, S10, S11, S12, F6, F7

S13, S14, S15, S16, F5

= Syrup

= Carbonated Water

= Non-Carbonated Water

Valve

Hidden on Non-

Flavor Shot Units

Hidden on Non-

Flavor Shot Units

Flavor Shots

Flavor Shots

Отзывы: