Mode Switching: 

The Audio path of the SPLICE-500™ MKII consists of two sections; the Input 
amplifier circuitry and the Output amplifier circuitry.  The SPLICE™ MKII’s unique 
circuitry mode switching allows the user to switch the audio path circuitry between 
classic Blackface and Blue Stripe modes, or mix and match between the two. 

When both Input & Output Mode LED’s are off (Black), the unit is configured for 
Blackface mode. 

When both Input & Output Mode LED’s are illuminated (Blue), the unit is configured 
for Blue Stripe Mode. 

Alternatively, the unit can be configured to mix and match the Input & Output circuits, 
creating entirely new sounds unique to the SPLICE™ MKII (i.e. Blue Stripe Input 
c Blackface Output circuit, or Blackface Input c Blue Stripe Output 
circuit) 

Note: The default mode when unit is powered on is Blackface. 

Note: The switching recovery time for Input mode switching is 
approximately 2 seconds when the release knob time is set to its fastest 
setting (fully clockwise).  Long release time settings will increase the Input 
switching mode cycle time.

 

Slam (AKA All Buttons In): 

Slam Mode is a high distortion mode, also known as “All Buttons In”.  Slam mode is 
engaged when the toggle switch is in the up position.  While in Slam mode, the Red 
“S” LED will illuminate when no gain reduction is present. 

Note: To achieve a classic Slam mode sound, the Ratio must be set to the 
“4” or “20” positions with Slam mode enabled.  Setting the ratio to 2, 8, or 
12 with slam mode enabled will result in different distortion effects. 

 

 

Содержание SPLICE-500 MKII

Страница 1: ... and built in the USA Through our dedication to advanced engineering high quality components and research from industry pros you can expect years of reliability and great customer service THANK YOU TABLE OF CONTENTS DESCRIPTION OVERVIEW 2 SPECIFICATIONS 2 INSTALLATION OPERATION 3 FRONT PANEL CONTROLS 3 MAINTENANCE AND CLEANING 8 WARRANTY 8 ...

Страница 2: ...Transformer Balanced Output With Mix Enabled 100 Ohm Output Impedance Transformer like Floating Output Electronically Balanced Accepts Balanced or Unbalanced Signals External Send 100 Ohm Output Impedance Transformer like Floating Output Electronically Balanced XLR Accepts Balanced or Unbalanced Signals External Return 22KHz Input Impedance Electronically Balanced XLR Accepts Balanced or Unbalance...

Страница 3: ...minimum of 5 minutes after power down before handling It is important to ensure adequate ventilation of the module while in operation The SPLICE 500 MKII should never be placed adjacent to another heat source or high power 500 module While it is not required it is recommended to leave a blank slot space to the right of the module in your 500 series rack to ensure adequate cooling and ventilation O...

Страница 4: ...pression that takes place after the input signal has crossed the threshold point The higher the ratio the more the signal that crosses the threshold will be compressed Ratios of 10 1 or higher are generally considered limiting rather than compression The SPLICE 500 MKII has stepped ratio times of 2 1 4 1 8 1 12 1 20 1 The Ratio has a control at its fully counterclockwise position labeled 1 which a...

Страница 5: ...in reduction At this point you may have too much of a good thing Simply turn the Wet signal down until you have blended in the desired amount of Dry signal Listen for overall amount of dynamics and control You should be able to dial in quickly and easily just the right amount for detail and density squeeze and sustain Meter The LED meter indicates gain reduction When no gain reduction is occurring...

Страница 6: ...unique to the SPLICE MKII i e Blue Stripe Input circuit Blackface Output circuit or Blackface Input circuit Blue Stripe Output circuit Note The default mode when unit is powered on is Blackface Note The switching recovery time for Input mode switching is approximately 2 seconds when the release knob time is set to its fastest setting fully clockwise Long release time settings will increase the Inp...

Страница 7: ...ing the Link toggle switch on both units to the up position 600R Loading Jumper The SPLICE 500 MKII allows for easily terminating the output signal with a 600R load for optimal signal transfer for use with both vintage and modern gear Note When connecting the SPLICE 500 MKII s output to vintage 600R equipment typically known as bridging the loading jumper should be disabled connected to pins 2 3 W...

Страница 8: ...g improper storage conditions power surges lightening or other natural disasters Warranty does not cover wear and tear items such as pots and switches or cosmetic wear Shipping and transport damages are not covered under warranty In the event of required maintenance within the warranty period unit should be returned to Serpent Audio or authorized repair facility Inbound freight charges are the res...

Отзывы: