3.1.2.3 Sub-Menu HEAT CURVE
T
his menu is used for making adjustments that affect the room temperature.For more information, please refer
to ”Adjustments to be made regularly” on page 20.
Table 1: Menu– HEAT CURVE
Menu Text
Description
Adjustable by
CURVE
The value entered shows the temperature of the water
to be distributed to the radiators (feed water
temperature) when the outside air temperature is 0°C.
used(see ”Adjustment
of CURVE value” on p18.)
MIN
Adjustment of value for lowest feed water temperature
allowed.
used(see ”Adjustment
of MIN & MAX value” on p22.
)
MAX
Adjustment of value for highest feed water
temperature allowed.
used(see ”Adjustment
of MIN & MAX value” on p22.
)
CURVE 5
Adjustment of room temperature when the outside air
temperature is +5°C.
used(see ”Adjustment
of CURVE value” on p18.)
CURVE 0
Adjustment of room temperature when the outside air
temperature is 0°C.
used(see ”Adjustment
of CURVE value” on p18.)
CURVE – 5
Adjustment of room temperature when the outside air
temperature is -5°C.
used(see ”Adjustment
of CURVE
.)
HIGH T STOP
When outdoor ambient temperature is higher than
this setting, the hot water to room will be stopped.
this setting is adjustable
from 0 to 50
ć
,factory
setting is 50
ć
.
LOW T STOP
When outdoor ambient temperature is lower than
this setting, the hot water to room will be stopped.
this setting is adjustable
from 0 to -50
ć
, factory
setting is -50
ć
.
value” on P18
LOW T° STOP
-50
HEATCURVE
CURVE
MIN
MAX
CURVE
5
CURVE
0
CURVE
-
5
40
22
70
0
0
0
HIGH T° STOP
50
11