1
/
16
LFP Storage System
LV3584 User Manual
Document No.
:
Version
V1.0
Страница 1: ...1 16 LFP Storage System LV3584 User Manual Document No Version V1 0 ...
Страница 2: ...ECTRICAL CHARACTER 13 3 1 MODULE SPECIFICATION 13 4 BATTERY MANAGEMENT SYSTEM BMS FUNCTION 14 5 PRODUCT EXTERIOR REQUIREMENT 14 6 DATA STORAGE REQUIREMENT 14 7 PACKING TRANSPORTATION STORAGE REQUIREMENTS 14 7 1 PRODUCT PACKAGE PACKING REQUIREMENTS 14 7 2 PRODUCT TRANSPORTATION REQUIREMENTS 14 7 3 PRODUCT STORAGE REQUIREMENT 14 8 REGULAR MAINTENANCE 15 8 1 SOC CHECK 15 8 2 CABLE CHECK 15 8 3 BALANC...
Страница 3: ...lation and operation To decrease the risk of human injury and make sure that the product is installed and operated safely you must read and follow all the descriptions announcements and warnings carefully Signs Danger Fatal Voltage Battery module would generate DC voltage and would cause fatal voltage and electric shock Only trained person can do the installation of the battery module Warning Dama...
Страница 4: ...areful Sign l Be Careful of Electric Shock Sign Don t put the system beside inflammables Sign Don t connect reversely Sign Don t put the system beside fire Sign Isolate the system from children and pets Sign Recycle Sign ...
Страница 5: ...ubber boots goggles Warning LV3584 system working temperature range 0 50 Proper temperature 18 28 If it exceeds the range the battery life cycle might be decreased or even cause battery system over low temperature warning or protection And may influence warranty Warning On the battery installation installers shall follow the local installation standards Attention Improper setting or service may pe...
Страница 6: ...nsert foreign matter to any part of the battery 1 2Before connection 1 Please firstly check the product and pack list after opening the case If there is any damage or missing please contact local dealer 2 Before installation please make sure that grid power is cut off and make sure that the battery is at Off condition 3 Connection must be correct don t connect battery reversely and make sure that ...
Страница 7: ...S Maximum Current 125A Pedestal Width 352mm Depth 570mm Height 60mm Power Cables Orange and Black 1xAWG3 Surlok Connector Communication Cable CAN RS485 communication cable Battery Output Surlok Port 2 2 Battery System Port Power Output Communication Power Switch SOC Display Status Indicator WiFi indicator Alarm Indicator ...
Страница 8: ...oltage Vdc 51 2 Battery Capacity AH 140 210 280 350 420 490 560 Module Number pcs 2 3 4 5 6 7 8 Module Energy kWh 3 584 Module Voltage Vdc 51 2 Module Capacity AH 70 Cell Number pcs 16 Charging Voltage Vdc 57 Nominal Charging Current A 28 42 56 70 84 98 112 Suggested Charging Current A 70 105 125 Charging Current A Max 15S 130 ...
Страница 9: ... W D H mm 570 352 537 570 352 693 570 352 849 570 352 1005 570 352 1161 570 352 1317 570 352 1473 Communication RS485 CAN Protection Level IP55 Weight kg Life Cycle Years 15 Working Temperature 0 50 Storage Temperature 20 60 Altitude M 2 000 Product Certificate IEC62619 CE Transport Certificate UN38 3 1 Controller Dimension W D H mm 2 Module Dimension W D H mm 3 Pedestal Dimension W D H mm 570 352...
Страница 10: ... judge through the data sent from the below batteries If the data sent from the batteries are judged to be normal the batteries would be started up successfully otherwise startup would fail 2 Shut down When the battery is not charged or discharged then you can shut down the battery The switch can be used to cut off the circuit when the battery is powering the loads But to protect outer devices we ...
Страница 11: ...low CAN Protocol used for communication between battery and inverter RS485 Communication Terminal RJ45 port Follow RS485 Protocol used for communication between battery and inverter CAN RS485 Baud Rate 500K Default 19200 Default No Description 1 CANH RS485A 2 CANL RS485B 3 GND GND 4 5 6 7 8 ...
Страница 12: ...ed on the battery data 5 WIFI and FAULT WIFI FAULT Status indicator Fault Indicator WiFi indicator 6 CAN Port CAN Used for communication 7 RS485 Port RS485 Used for communication 8 Input Output Port Battery Input Output Port 9 Input Output Port Battery Input Output Port 2 6 Package LV3584 Box Inner Dimension 650mm 430mm 260mm Outer Dimension 670mm 445mm 280mm LV3584 Accessory Box Outer Dimension 6...
Страница 13: ...ge 57V charge until discharge current 0 01C 3 1 4Nominal Discharge Current 35A 3 1 5Discharging Protect Current 125A 15s delay protection 1 minute after protection resume or directly resume when there is charge current 3 1 6Nominal Charging Current 35A 3 1 7 Charging Protect Current 125A 15s delay protection 1 minute after protection resume or directly resume when there is discharge current 3 1 8B...
Страница 14: ...ificate Standard 2 Especially the package must follow Revised Special Rule of Road Cargo Transportation and Existing Dangerous Goods Act 7 2 Product Transportation Requirements Battery must be prevented from strong shaking impact extrusion and must be prevented from sunlight and rain The battery can be transported through car train boat air etc for transportation The battery shall be lightly moved...
Страница 15: ...be achieved automatically through communication between system and outer devices 8 4 Output Relay Check When load is small low current control the switch of output relay to hear the sound from the relay so that you will know that the relay is working normally 8 5 History Check Analyze history records check whether there is accident warning protection and analyze on the reasons 8 6 Maintenance For ...
Страница 16: ... please contact us Shanghai Sermatec Energy Technology Co Ltd Address 1388 Xindian Road Jiading District Shanghai China Phone No 86 021 69986891 Product Demand Email presales sermatec ess com Technical Support Email support sermatec ess com ...