Serialio.com BlueSnap AAA V 4.30SIO 3/17/2009 page 5
*** OTHER COMMANDS ***
Example of result from “B” Battery Power command:
UP=62,PWR=1731,Batt=2FE,2298 mv
UP= seconds since being powered up.
PWR= charger reading. has to be > 1000 (this is hex) if < 1000 no charger running.
Batt= battery reading in HEX (this is the actually battery voltage / 3 referenced to 3.3V ).
2298 this is the actual battery voltage in millivolts.
A complete list of commands can be
found in Advanced Command Guide
CMD
DESCRIPTION
D
Basic Settings
E
Extended Settings
G<X>
A single setting matching the commands above
GB
Bluetooth Address of this device
&
I/O Ports (shows the value of the switches)
V
Firmware Revision
B
Returns information about Battery Power
CMD VAL1
VAL2
DESCRIPTION
C <addr>
Connect to Remote Address( in Master Mode only)
H
Help, Show list of commands
I <time> <COD> Inquiry Scan, time= xx seconds ,optional COD filter
R 1
Reboot device immediate
U <rate> <E,O,N> Temporary UART Change, immediate, not stored