Serial Cables PCI-ENC8G-24UM-2X2 Скачать руководство пользователя страница 3

3

Go Top ↑

1.  Package Checklist

2.  Storage Enclosure Description

2.1 Front panel

Before the installation of the enclosure, verify that the items below are 

included in the package:

A. PCI-ENC8G-24UM-2X2 enclosure × 1

B. U.2 SSD drive tray (already installed in PCI-ENC8G-24UM-2X2) × 24

C. U.2 SSD mounting screw × 96

D. Power cords × 2

E. Host card 

Optional: 

 

(number of host cards and cables depends on which mode selected; see section 4)

F. HD mini-SAS (SFF-8644) to HD mini-SAS (SFF-8644) data cables 

1. SSD activity and faullt LEDs

      

Flashing blue – Access

      

Red – U.2 SSD fails

2. SSD presence LED

      

White – Power on

3. LCD module

1

Sl ot No.

2

3 ......

...... 22 23 24

* Please check the requirements in

 Section 4.

Содержание PCI-ENC8G-24UM-2X2

Страница 1: ...First edition Mar 2020 User s Manual PCI ENC8G 24UM 2X2 2U 24 Bay NVMe JBOF...

Страница 2: ...scription 3 3 5 LCD Configuration 15 4 Switch Mode 10 3 Enclosure Installation 6 6 CLI Manager 18 21 CLI Command 17 LCD setup item hierarchical menu 10 4 1 mode 1 13 4 2 mode 2 14 4 3 mode 3 3 2 1 Fro...

Страница 3: ...already installed in PCI ENC8G 24UM 2X2 24 C U 2 SSD mounting screw 96 D Power cords 2 E Host card Optional number of host cards and cables depends on which mode selected see section 4 F HD mini SAS...

Страница 4: ...uzzer beeping inside the enclosure 3 Link indicator LED Solid red PCIe link is not at full lanes No light PCIe link is at full lanes 3 Link indicator LED Solid red PCIe link is not at full lanes No li...

Страница 5: ...ccurs the buzzer on the switch board inside the switch board inside PCI ENC8G 24UM 2X2 NVMe JBOF will beep To mute the buzzer beeping press PCIe switch board A and B s mute buttons under th e LAN port...

Страница 6: ...ure from its packaging and place the enclosure next to computer server or workstation 2 Hold one of the U 2 drive trays from the enclosure and push its button downward for the release of the lever unt...

Страница 7: ...to shut and then press the lever to close until it clicks to ensure that the U 2 drive module is within the enclosure Do not force the levers to close while you insert U 2 drive modules into the encl...

Страница 8: ...4 data cables Connection types between PCI ENC8G 24UM 2X2 and host server are shown at section 4 of the user s manual 8 The PCI ENC8G 24UM 2X2 enclosure is with redundant PSU so connect one end of the...

Страница 9: ...After the two power cords are connected you can press the power button for one second on the LCD module in front of PCI ENC8G 24UM 2X2 to power on the NVMe JBOF and then power on the server computer U...

Страница 10: ...U 2 NVMe SSD Server 1 can access U 2 NVMe SSDs from slot 1 through slot 24 1 Mode 1 When using only one server one host card and wishing host connection throughput up to 128 Gbps please use connection...

Страница 11: ...one server two host cards and wishing doubled host connection throughput up to 256 Gbps please use connection Type B for the system Connection type B is for one server with two host cards installed ha...

Страница 12: ...VMe SSDs from slot 1 through slot 24 Server 2 can access U 2 NVMe SSDs from slot 1 through slot 24 Connection type C is for connecting to two servers with each server having access to twenty four U 2...

Страница 13: ...Server 3 can access U 2 NVMe SSDs from slot 13 through slot 24 Server 4 can access U 2 NVMe SSDs from slot 1 through slot 12 2 Mode 2 Mode 2 is for connecting to up to four servers with each server ha...

Страница 14: ...h slot 18 Server 6 can access U 2 NVMe SSDs from slot 19 through slot 24 Server 7 can access U 2 NVMe SSDs from slot 1 through slot 6 Server 8 can access U 2 NVMe SSDs from slot 7 through slot 12 3 Mo...

Страница 15: ...r function keys with the LEDs on the LCD module in front of the PCI ENC8G 24UM 2X2 NVMe JBOF 1 Power on Mute Return button Power on press one second to power on the PCI ENC8G 24UM 2X2 NVMe JBOF Mute p...

Страница 16: ...button to go back to the previous display of screen As a main item is selected the related information or sub items will be shown under the main item 6 PSU LED PSU normal no light PSU failure red 7 F...

Страница 17: ...Temp 3 PSU 1 PSU 2 Switch A Switch B Switch A Switch B Link Status Enter Password Enter Password Enter old password Temp 1 Temp 2 Temp 1 Temp 2 Slot 1 Slot 2 Slot 3 Slot 24 Slot 1 Slot 2 Slot 3 Slot...

Страница 18: ...emulation program The program installation procedure must be done before proceeding to the CLI function Whichever terminal emulation program is used it must support the XMODEM file transfer protocol S...

Страница 19: ...switch controller and the VT100 Terminal emulation please configure the VT100 Terminal emulation settings to the values as below For Port select COM3 COM3 is the example actual COM number will depend...

Страница 20: ...20 Step 3 Select the Terminal emulation type please go to the Terminal section as shown below For Terminal ID select VT100 Click OK when the selection is finished...

Страница 21: ...how internal temperature of PCIe switch bind Slot No enter bind Bind any all ports into switch group unbind Slot No enter Unbind any all ports from switch group showbind Slot No enter showbind Show bi...

Страница 22: ...ovides an online table of contents providing brief description of the supported command groups and built in commands The help command can be used to get the detailed information about the CLI commands...

Страница 23: ...23 eth command Ethernet IP configuration Syntax JBOF eth enter setmac command Set Ethernet MAC Media Access Control address Syntax JBOF setmac enter...

Страница 24: ...via PCI ENC8G 24UM 2X2 s rear USB Type B port rather than its rear RJ 45 LAN port fdl command Update PCIe switch firmware Syntax JBOF fdl sw enter lsd command The command shows environmental informat...

Страница 25: ...BOF showfan enter buz Command The command is for controlling the buzzer on PCIe switch board en enable the buzzer function for all time dis disable the buzzer function for all time on allow buzzer to...

Страница 26: ...dpwr command The command is for controlling the power of each U 2 NVMe drive slot Syntax JBOF ssdpwr Slot No on or off enter ssd_reset command To reset each U 2 NVMe SSD Syntax JBOF ssd_reset Slot No...

Страница 27: ...n on all U 2 NVMe drive slots and ports t top switch controller board b bottom switch controller board Syntax JBOF showport t b enter showslot command The command shows link speed and link width infor...

Страница 28: ...etting configuration mode for PCIe switch board 1 set for mode 1 2 set for mode 2 3 set for mode 3 Syntax JBOF setmode 1 2 3 enter showmode command The command shows configuration mode for each PCIe s...

Страница 29: ...mp command The command show internal temperature of PCIe switch Syntax JBOF showtemp enter bind command The command bind any all ports into switch group Syntax JBOF bind Slot No enter Applicate in Mod...

Страница 30: ...d Applicate in Mode 4 only The command unbind any all ports from switch group Syntax JBOF unbind Slot No enter showbind command Applicate in Mode 4 only The command show binding info Syntax JBOF unbin...

Страница 31: ...mand shows position information for switch controller board within PCI ENC8G 24UM 2X2 NVMe JBOF Syntax JBOF pos enter ver command The command shows controller firmware version on PCIe switch board Syn...

Страница 32: ...ct your regional distributor or Serial Cables LLC Serial Cables LLC reset command To reset the PCIe switch board Syntax JBOF reset enter 8811 American Way Suite 110 Englewood CO 80112 www serialcables...

Отзывы: