www.SereneLifeHome.com
14
ER 5
ER 6
ER 7
Overload
protection
Motor not
connected
Controller
receives no
signal
ER 13
ER 14
IGBT Short
circuit
Load Short
SAFE
Security
lock off
1. Check for overload.
2. Check if the mechanical moving parts are stuck.
3. Check if there is a lack of release agent. If there is a
lack of release agent, the friction between the
running belt and the running plate will increase.
4. Check the running plate for serious wear.
5. Check the running belt for serious wear.
6. Check if the motor cable is short-circuited.
7. Check or replace the controller.
8. Check or replace the motor.
1. Check if the motor cable is loose or falling off.
2. Check or replace the motor.
3. Check or replace the controller.
1. Check for loose, dropped or damaged
communications lines.
2. Check or replace the electronic watch board.
3. Check or replace the controller.
1. Check if the machine has strong interference signals.
2. Check or replace the controller.
1. Check if there is a foreign object in the controller
output that leads to a short circuit.
2. Check or replace the motor.
1. Check if the security lock is in place and safety
switch is in position.
2. Check if the safety lock is good, and the magnetic
ring pipe is broken and replaced.