APPLICATION

This pump is used primarily as cellar pump. When installed in a shaft, the pump 

provides protection from flooding. It is also used wherever water has  to be 

moved from one place to another, e.g. in the home, agriculture, horticulture, 

plumbing and many other applications. 

Not suitable for professional use.

SAFETY FIRST!

 • 

Read this manual and general safety instructions carefully before using the 

    appliance, for your own safety. Your power tool should only be passed on together  
    with these Instructions.

 • 

To reduce risk of electrical shock, always disconnect the pump from the power  

    source before handling or servicing. 

 • 

DO NOT

 pump hazardous materials (flammable, caustic, etc.) unless the pump is  

    specifically designed and designated to handle them.

 • 

DO NOT

 block or restrict discharge hose, as discharge hose may whip under   

    pressure.

 • 

DO NOT

 wear loose clothing that may become entangled in the impeller or other  

    moving parts.

 • 

Keep clear of suction and discharge openings. 

DO NOT

 insert fingers in pump  

    with power connected.

 • 

Always wear eye protection when working on pumps.

 • 

DO NOT

 exceed manufacturers recommendation for maximum performance, as  

    this could cause the motor to overheat.

 • 

DO NOT 

remove cord and strain relief. Do not connect conduit to pump.

 • 

WARNING!

 Cable should be protected at all times to avoid punctures, cut, bruises  

    and abrasions - inspect frequently. Never handle connected power cords with
    wet hands.

 • 

WARNING!

 To reduce risk of electrical shock, all wiring and junction connections  

    should be made per the NEC or CEC and applicable state or province and local
    codes. Requirements may vary depending on usage and location.

 • 

WARNING!

 Submersible Pumps are not approved for use in swimming pools,  

    recreational water installations, decorative fountains or any installation where  
    human contact with the pumped fluid is common.

      IMPORTANT!

We are not responsible for losses, injury, or death resulting from a failure to 

observe these safety precautions, misuse or abuse of pumps or equipment.

       

When parts are missing or damaged, please contact your dealer.

Содержание SLBSMPMP100

Страница 1: ...Submersible Clean Dirty Water Pump SLBSMPMP50 SLBSMPMP50 9 SLBSMPMP100 Powerful Sump Pump 1980 GPH Auto Float Switch with 16 ft Power Cord Length ...

Страница 2: ...moving parts Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT remove cord and strain relief Do not connect conduit to pump WARNING Cable should be protected at all times to avoid punctures...

Страница 3: ...ion it must be equipped with a PRCD residual current circuit breaker with a nominal trip current of max 30 mA according to VDE 0100 part 702 and 738 The pump must not be operated while people are in the swimming pool or in the garden pond Please contact your electrician ATTENTION Before starting to run your new submersible pump please have the following items checked by an expert Ground connection...

Страница 4: ...mum temperature of 35 C or 95 F This pump may not be used for other fluids especially motor fuels cleaning fluids and other chemical products PARTS DESCRIPTION 1 2 3 4 5 1 2 3 4 5 1 Motor housing 2 Water inlet 3 Water outlet 4 Cable plug 5 Floating switch 6 Carrying handle SLBSMPMP50 and SLBSMPMP50 9 SLBSMPMP100 ...

Страница 5: ... minimum dimensions of 40 x 40 x 50 cm so that the floating switch can move freely MAINS SUPPLY Your new submersible pump is equipped with a shock proof plug according to regulations The pump is designed to be connected to a 220V 50Hz earthed socket Make sure that the socket is sufficiently secured min 6 Amp and is in excellent condition Introduce the plug into the socket and the pump is ready to ...

Страница 6: ...ance between the float switch head and the latching holder is not too small Proper operation is not guaranteed if the gap is too small When you set the float switch make sure that it does not touch the base before the pump switches off Caution Risk of dry running This appliance cannot be used by children or people who are physically mentally or developmentally impaired or people who lack experienc...

Страница 7: ...must be replaced by our after sales service department If the connecting cable or mains plug is damaged it must be replaced by a particular connecting cable which is available from our service department Replacement of the connecting cable must only be carried out by our service department see last page or by a qualified person qualified electrician STORAGE Thoroughly clean the whole machine and i...

Страница 8: ...ce worn out parts Insufficient flow Pump switches off after short operation period Thermal cutout stops pumps due to dirty water water too hot thermal cutout stops pumping Remove mains plug clean pump and shaft Make sure that a water temperature of max 35 C 95 F is not exceed www SereneLifeHome com 7 TROUBLESHOOTING SLBSMPMP50 9 SLBSMPMP100 Power Supply Qmax H Max Product Dimension L x W x H 400W ...

Страница 9: ...e Thermoplastic Body Resists Corrosion Great to Drain the Dirty Water from the Pond Garden Pond or Water Tanks Perfect for Household Utility Applications of Transferring Water from One place to Another WHAT S IN THE BOX 1 Water Pump 3 Power Adapters TECHNICAL SPECS Construction Material Engineered ABS and Metal Power Output AC 110V 60Hz Power Cord Length 16 feet Type Water Pump blue Diameter of Pi...

Страница 10: ...Questions Issues We are here to help Phone 1 718 535 1800 Email support pyleusa com ...