background image

TECHNICAL DATA

Installation is to be performed in the complete absence of any

voltage.

Power supply voltage: .....................................................................10.8 ÷ 13.8Vdc

Maximum consumption: ....................................................................47mA@12Vdc

Radiofrequency: ....................................................................................433.92MHz

Type of transmission:...................................................... variable code (rolling code)

Reception distance in free space:...........................100m with wire antenna supplied

............................................................................200m with optional OG/50 antenna

Channel 1 output: ...............................................................................open collector

Channel 2 output: .............1 relay with 1 voltage free changeover max. [email protected]

Maximum number of different storable remotes:....................................................33

Wiring: ............................................................................use 0.5sqmm section wires

Maximum dimensions (Lx H x P):......................................................50 x 70 x 20mm

Weight: ...............................................................................................................35g

Operating temperature:..........................................................................-10 ÷ +40°C

Storage temperature:.............................................................................-20 ÷ +60°C

Maximum relative humidity: ................................................95% without condensate

Protection rating IP: ..............................................................................................00

RX/90 may be inserted in the shell of the Fenice control unit or installed outside, in

which case it should be inserted in a non metallic case that affords adequate

protection.

No particular maintenance is required.

PRODUCT CATEGORYAND INTENDED USE

DIRECTIVES

GENERIC STANDARDS

SPECIFIC PRODUCT STANDARDS

It is the installer's responsibility to comply with all the recommendations contained in this

instruction manual, as well as with standards and laws relevant to the plant to be installed, even if

not specified herein.

Electronic, non-automatic device, for use in residential, commercial and light industrial settings,

designed to receive a control signal in radio frequency, implemented by means of open collector or relay

output. The intended use is exclusively in conjunction with SERAI burglar alarm control units of the

FENICE range.

Low voltage Directive (LVD):..................................................................................................2006/95/EC

Electromagnetic compatibility Directive (EMC): ...................................................................2004/108/EC

Directive on radio and telecommunications terminal equipment (R&TTE): ...............................1999/5/EC

Directive on Restriction of Hazardous Substances (RoHS):...................................................2011/65/UE

European electrical safety standard:.....................................................................................EN 60335-1

European EMC standard - immunity: ..................................................................................EN 61000-6-1

European EMC standard - emissions:.................................................................................EN 61000-6-3

European Standards relative to R&TTE (SRD): .......................EN 300220-1+EN301489-1+EN301489-3

Non-automatic control devices for fixed electrical installation.................................................EN 60669-1

2nd CHANNEL

1st CHANNEL

With a tool that affords double insulation, press the

button of the selected channel for approximately 1s.

The corresponding yellow LED lights up steadily.

Press the remote control button which you wish to control that channel with. The receiver's

yellow LED flashes briefly and then stays on steadily: remote saved.

It is not necessary to perform self-learning of the clones of an already programmed transmitter,

since they are automatically programmed simply any time they are used, without accessing the

receiver.

PRESS
FOR 1s

ATTENTION!

If storing does not occur when the transmitter button is pressed, then the

transmitter button you have pressed has already been saved for that

particular channel, the transmitter is faulty or the battery is down.

ATTENTION!

Do not keep the button pressed for 5s or longer, otherwise all previously programmed codes

will be deleted.

PREMERE
BREVEMENTE

SELF LEARNING OF TX/92 REMOTE CONTROLS WITH RX/90 RECEIVER

RX/90 RECEIVER

1

2

!

3

4

Repeat sequence

from point 2 to store

other remote controls.

To exit programming press the

receiver button briefly or wait about 2

minutes. The yellow LED should go

out.

!

To cancel programming of one of the two channels, keep the button of

the selected channel pressed for at least 5s until the relevant yellow LED

starts flashing quickly (cancellation in progress). Release the button and

wait for the LED to stay on steadily: the greater the number of remotes

stored, the longer it takes for the cancellation.

Upon completing cancellation, the LED stays on steadily, in self-learning

mode for the selected channel. Proceed from point 2 of the above

procedure.

LIGHT ON

PRESS FOR
AT LEAST 5s

FLASHING LIGHT

ATTENTION!

This procedure cancels all programmed transmitters for the selected channel only. If necessary repeat it for the other channel. In

order to re-program transmitters in relation to the deleted channel, the self-learning procedure must be performed again.

!

RX/90 RECEIVER

LUCE SPENTA

LUCE ACCESA

2nd CHANNEL

1st CHANNEL

CANCELLATION OF ALL REMOTE CONTROLS ASSOCIATED TO A CHANNEL

CE DECLARATION OF CONFORMITY

SERAI srl hereby declares that the

RX/90 was designed and manufactured in full compliance with the above mentioned directives and standards.

product

2011/65/UE DIRECTIVEABOUT THE RESTRICTION OF THE USE OF CERTAIN HAZARDOUS SUBSTANCES IN ELECTRICALAND ELECTRONIC EQUIPMENT (RoHS)

2012/19/UE DIRECTIVEABOUT THE WASTE OF ELECTRICALAND ELECTRONIC EQUIPMENT (WEEE)

This device was manufactured according to the restrictions set by the RoHS directive. To protect the environment: when no longer needed, the device must not be disposed of as mixed municipal

waste. Take it to an appropriate WEEE (Waste of Electric and Electronic Equipment) waste collection facility.

M A D E

I N

I T A L Y

VIA ENRICO FERMI, 22
35020 LEGNARO - PADOVA
I

T

A

L

Y

+39 049 79 08 58
+39 049 88 30 529

[email protected]
w w w. s e r a i . c o m

E L E T T R O N I C A

P A D O V A

WARRANTYCONDITIONS

The company reserves the right to make any modification without prior notice. The conventional SERAI product warranty is valid 24 months following the issuance of the fiscal document attesting to its purchase. Services

covered by the warranty are provided at the company's facilities in Legnaro (PD - ITALY) or at any one of the company's authorized Service Centres. The relative shipping and transport costs are at the Customer's

expense. For TechnicalAssistance call: +39.049.790.858, Monday to Friday 8:30 to 12:30 and 14:00 to 18:00. The warranty shall be retained void in the event of any tampering with the product or in the event that the label

specifying the product's production batch has been broken or removed.

Отзывы: