TECHNICAL DATA
Installation is to be performed in the complete absence of any
voltage.
Power supply voltage: .....................................................................10.8 ÷ 13.8Vdc
Maximum consumption: ....................................................................47mA@12Vdc
Radiofrequency: ....................................................................................433.92MHz
Type of transmission:...................................................... variable code (rolling code)
Reception distance in free space:...........................100m with wire antenna supplied
............................................................................200m with optional OG/50 antenna
Channel 1 output: ...............................................................................open collector
Channel 2 output: .............1 relay with 1 voltage free changeover max. [email protected]
Maximum number of different storable remotes:....................................................33
Wiring: ............................................................................use 0.5sqmm section wires
Maximum dimensions (Lx H x P):......................................................50 x 70 x 20mm
Weight: ...............................................................................................................35g
Operating temperature:..........................................................................-10 ÷ +40°C
Storage temperature:.............................................................................-20 ÷ +60°C
Maximum relative humidity: ................................................95% without condensate
Protection rating IP: ..............................................................................................00
RX/90 may be inserted in the shell of the Fenice control unit or installed outside, in
which case it should be inserted in a non metallic case that affords adequate
protection.
No particular maintenance is required.
PRODUCT CATEGORYAND INTENDED USE
DIRECTIVES
GENERIC STANDARDS
SPECIFIC PRODUCT STANDARDS
It is the installer's responsibility to comply with all the recommendations contained in this
instruction manual, as well as with standards and laws relevant to the plant to be installed, even if
not specified herein.
Electronic, non-automatic device, for use in residential, commercial and light industrial settings,
designed to receive a control signal in radio frequency, implemented by means of open collector or relay
output. The intended use is exclusively in conjunction with SERAI burglar alarm control units of the
FENICE range.
Low voltage Directive (LVD):..................................................................................................2006/95/EC
Electromagnetic compatibility Directive (EMC): ...................................................................2004/108/EC
Directive on radio and telecommunications terminal equipment (R&TTE): ...............................1999/5/EC
Directive on Restriction of Hazardous Substances (RoHS):...................................................2011/65/UE
European electrical safety standard:.....................................................................................EN 60335-1
European EMC standard - immunity: ..................................................................................EN 61000-6-1
European EMC standard - emissions:.................................................................................EN 61000-6-3
European Standards relative to R&TTE (SRD): .......................EN 300220-1+EN301489-1+EN301489-3
Non-automatic control devices for fixed electrical installation.................................................EN 60669-1
2nd CHANNEL
1st CHANNEL
With a tool that affords double insulation, press the
button of the selected channel for approximately 1s.
The corresponding yellow LED lights up steadily.
Press the remote control button which you wish to control that channel with. The receiver's
yellow LED flashes briefly and then stays on steadily: remote saved.
It is not necessary to perform self-learning of the clones of an already programmed transmitter,
since they are automatically programmed simply any time they are used, without accessing the
receiver.
PRESS
FOR 1s
ATTENTION!
If storing does not occur when the transmitter button is pressed, then the
transmitter button you have pressed has already been saved for that
particular channel, the transmitter is faulty or the battery is down.
ATTENTION!
Do not keep the button pressed for 5s or longer, otherwise all previously programmed codes
will be deleted.
PREMERE
BREVEMENTE
SELF LEARNING OF TX/92 REMOTE CONTROLS WITH RX/90 RECEIVER
RX/90 RECEIVER
1
2
!
3
4
Repeat sequence
from point 2 to store
other remote controls.
To exit programming press the
receiver button briefly or wait about 2
minutes. The yellow LED should go
out.
!
To cancel programming of one of the two channels, keep the button of
the selected channel pressed for at least 5s until the relevant yellow LED
starts flashing quickly (cancellation in progress). Release the button and
wait for the LED to stay on steadily: the greater the number of remotes
stored, the longer it takes for the cancellation.
Upon completing cancellation, the LED stays on steadily, in self-learning
mode for the selected channel. Proceed from point 2 of the above
procedure.
LIGHT ON
PRESS FOR
AT LEAST 5s
FLASHING LIGHT
ATTENTION!
This procedure cancels all programmed transmitters for the selected channel only. If necessary repeat it for the other channel. In
order to re-program transmitters in relation to the deleted channel, the self-learning procedure must be performed again.
!
RX/90 RECEIVER
LUCE SPENTA
LUCE ACCESA
2nd CHANNEL
1st CHANNEL
CANCELLATION OF ALL REMOTE CONTROLS ASSOCIATED TO A CHANNEL
CE DECLARATION OF CONFORMITY
SERAI srl hereby declares that the
RX/90 was designed and manufactured in full compliance with the above mentioned directives and standards.
product
2011/65/UE DIRECTIVEABOUT THE RESTRICTION OF THE USE OF CERTAIN HAZARDOUS SUBSTANCES IN ELECTRICALAND ELECTRONIC EQUIPMENT (RoHS)
2012/19/UE DIRECTIVEABOUT THE WASTE OF ELECTRICALAND ELECTRONIC EQUIPMENT (WEEE)
This device was manufactured according to the restrictions set by the RoHS directive. To protect the environment: when no longer needed, the device must not be disposed of as mixed municipal
waste. Take it to an appropriate WEEE (Waste of Electric and Electronic Equipment) waste collection facility.
M A D E
I N
I T A L Y
VIA ENRICO FERMI, 22
35020 LEGNARO - PADOVA
I
T
A
L
Y
+39 049 79 08 58
+39 049 88 30 529
[email protected]
w w w. s e r a i . c o m
E L E T T R O N I C A
P A D O V A
WARRANTYCONDITIONS
The company reserves the right to make any modification without prior notice. The conventional SERAI product warranty is valid 24 months following the issuance of the fiscal document attesting to its purchase. Services
covered by the warranty are provided at the company's facilities in Legnaro (PD - ITALY) or at any one of the company's authorized Service Centres. The relative shipping and transport costs are at the Customer's
expense. For TechnicalAssistance call: +39.049.790.858, Monday to Friday 8:30 to 12:30 and 14:00 to 18:00. The warranty shall be retained void in the event of any tampering with the product or in the event that the label
specifying the product's production batch has been broken or removed.