background image

DA

L  

19

65

Pag. 1/5

M

T

/2

A

+

C

F

/2

A

  

 E

MT/2A - 

03.2A

  

UNDERGROUND MOTOR FOR WING GATES UP TO

 3

,00 m AND 250 Kg 

EACH WING -  230Vac

CF/2A - 

03.CF

  

FOUNDATION BOX

E

R

A

I

S

GATE AUTOMATION DIVISION

INSTALLATION MANUAL

!

Thank you for choosing a SERAI ELETTRONICA product, which we are confident will perform to your requirements.

Please be advised that you are about to fit a

 system 

classified as “a power-operated drive designed to move automatic ga-

tes and doors in commercial or residential buildings accessed by vehicles and persons”, and as such, the system must be 
considered 

potentially hazardous

. By law, you are responsible for rendering this equipment as “safe” as is reasonably pos-

sible.

Installation and maintenance of equipment of this kind must therefore be carried out by 

skilled, qualified and trained 

personnel, working in a professional manner

, as provided for by law n. 46/90 and any subsequent amendments and 

supplements. 

The law in question prohibits the construction of these types of systems by non-qualified personnel

.

SERAI manufacturing complies with the following legislation:

Applicable directives for the CE marking 

:

Machines:

98/37/EEC

Low Voltage:

73/23/EEC

Electromagnetic Compatibility:

89/336/EEC

General applicable standards

:

Electrical Safety:

IEC EN60335-1 + IEC EN60335-2-103 

Electromagnetic Compatibility - Emissions:

CEI EN61000-6-3

Electromagnetic Compatibility - Immunity:

CEI EN61000-6-

Apart from the legislation mentioned above, you are also reminded to comply with the following standards during the 
installation phase.

General applicable standards

:

Safety of electrical systems in non-specialised environments:

CEI 64-8

Specific product standards applicable

:

Safety in the use of power-operated doors - requirements:

UNI EN12453

Safety in the use of power-operated doors - testing methods:

UNI EN12445

SERAI products enable users to build systems which comply with these standards. This is extremely important as

 

THE INSTALLER IS LIABLE FOR THE SYSTEM AND FOR ENSURING ITS OPERATION COMPLIES WITH 
LEGAL PROVISIONS.

This handbook must be read in full before proceeding with the installation of the various parts of the system.

The installation of the mechanical end stops for gate opening and closure is necessary for system safety purposes 
and therefore this operation must be performed before proceeding with the installation of the control unit.

Отзывы: