Solenoid diaphragm pump
Series R/RS 204.1
Operating Instructions
TA 416
Rev.
11 en
04/2013
Subject to technical modifications!
www.sera-web.com
41
Unscrew working diaphragm from connecting rod
(see Fig. 43)
Base ring
Connecting rod
Insert
Working diaphragm
Fig. 43 (Disassembly of working diaphragm)
Screw working diaphragm onto connecting rod
Set stroke length to 50 %
Put pump body onto base ring. Tighten fixing screws
crosswise with correct torque (see Chapter. 8.1 / Ta-
ble.09).
When mounting the pump body please note:
CAUTION !
Pressure valve above; suction valve below !
(Consider the direction of the arrows on the valves, described
in Chapter 7.2.5)
Note direction of arrow on pump body
Fix suction and pressure line
Reset original stroke length
Apply voltage
The solenoid diaphragm pump is ready for operation
12
Fault analysis and corrective action
sera
- products are sophisticated technical products which are
only shipped after having been thoroughly tested and checked
at our factory.
Should there be any faults, these can be detected and rectified
easily and quickly if the steps in Table 14 are carried out.