10
RS-232 COMMAND REFERENCE
Display Status
Syntax:
DS
or
status
Description: Display the identity and status of the LISST-AOBS. NOTE: future firmware
versions may include more information in the response.
Example:
LISST-AOBS>DS
Serial number: 6260
SDI-12 address: 0
Version 2.10 Apr 13 2021 22:59:53
Input voltage is 12.46
LISST-AOBS>
Get and Transmit Sample
Syntax:
GS
or
getsample
Description: Instrument makes a measurement (for approximately 1 second) and returns
the ABS, OBS and AOBS values.
Example:
LISST-AOBS>GS
+4.66e+01,+1.004,+8.78e+02
LISST-AOBS>
Start free-running data
Syntax:
GO
or
GO
period
Description: Starts free-running mode. If a numeric
period
value is included, that will set the
time between samples, in seconds. If no
period
is included, the period is 1
second. Data will continue indefinitely, until stopped by 3 ctrl-C or carriage-
return characters are received, or an SDI-12 command is received.
Examples:
LISST-AOBS>GO
+4.66e+01,+1.004,+8.78e+02
+4.66e+01,+1.004,+8.78e+02
+4.66e+01,+1.004,+8.78e+02
…
LISST-AOBS>GO 3
+4.66e+01,+1.004,+8.78e+02
[3-second pause]
+4.66e+01,+1.004,+8.78e+02
[3-second pause]
+4.66e+01,+1.004,+8.78e+02
[3-second pause]
…