SEP
120
/
360
/
900
ST
www.sepura-technologies.com
installation manual
1
Before Starting Assembly, please
check contents are as follows:
•
1
White Felt Bag Filter with black tube
•
1
Silexa Filter
•
1
Test Bottle
•
1
Cleaner Tower (120,360 or 900)
•
1
Drilled Lid
•
-
Metal Retaining Springs
SEP120
= 1 x 170mm
SEP360
= 1 x 250mm
SEP900
= 2 x 400mm
Service interval kit comprising;
• moulded plastic mount + screw
• printed card
• self-adhesive Timestrip.
Fitting kit containing;
•
1
Straight adaptor 15mm x 1/2” BSP
•
1
Blanking Plug - large
•
1
Elbow
15mm
•
1
Assembled Porting Block
•
3
Porting Block Small Blanking Plugs
•
4
Screw 4.8x45mm and washers
•
2
Grab
Taps
•
1
Blue nylon adaptor
•
1
Black
Tube:
SEP120
= 73mm
SEP360
= 100mm
SEP900
= 180mm
Insert the boss on the reverse of
the mount
(c)
into the pre-drilled
hole in the separator lid.
Peel backing from timestrip
(a)
and attach to the plastic card
(b)
within the dotted lines.
Flex the card, passing the ends
through the slots on the top
surface of the mount.
To activate,
press firmly on
the timestrip label at the
point indicated.
After a few minutes a red line
will appear, to indicate ‘time in
service’ up to 12 months
A replacement card and
timestrip will be supplied with
each service kit
.
i
ii
iii
General Installation notes
•
Please ensure a steady
fall in the pipe run from
the outlet point to the
foul drain.
•
Never discharge
condensate to a storm
drain or to surface water;
always connect to a foul
drain or sewer.
•
Remember that it’s the
user’s responsibility to
check with the local
authority as to the
permissible discharges
in their area.
Testing Quality
Replace filters before outlet
cloudiness exceeds the ppm
limit for your region.
Test outlet quality weekly
using kit provided.
Further information is available on our website below.
(c)
(b)
(a)
Service Indicator -
assembly and attachment
superior
technologies